| 3/2-Funktion und Anfangszustand | Sizes 05 (0500 series), 1 (100), 2 (200), 3 (300). 10 single-solenoid requires NC normally closed or NO normally open. 20 double-solenoid ordering note states no selectable initial-state field. The internal-structure drawing labels 6STV120NC despite that note; double-solenoid codes bearing NC/NO require technical confirmation, not an automatic state assumption. |
| Druck und Medium | Pilot-operated 3/2 valve. Operating pressure 0.15–0.8MPa; proof pressure 1.2MPa is not service pressure. Air filtered through 40 μm or finer; aluminum alloy; −20 to 70°C. Main and pilot exhaust are centralized. No separately encoded external-pilot option is published. |
| Schmierung und Schaltzeit | Lubrication not required; if used, continue without interruption, ISO VG32 or equivalent. Maximum 5 cycles/s is no-load. Excitation 0.05 s or below is not a complete machine-cycle guarantee. Initial state/manual override does not certify a machine safety stop. |
| Anschlussmatrix | 0500 M5: inlet/outlet/exhaust M5. 100 M5 or 06: all M5 or all 1/8. 200 06: all 1/8; 08: inlet/outlet 1/4, exhaust 1/8. 300 10: inlet/outlet 3/8, exhaust 1/4. Inch thread blank PT; G G-thread; T NPT. M5 has no thread suffix. |
| Veröffentlichter Durchfluss | 0500 M5 area 4.25 mm²/Cv 0.25; 100 06 area 12.3/Cv 0.7; 200 08 area 17.9/Cv 1.05; 300 10 area 38.4/Cv 2.25. The 100 M5 and 200 06 are not individually rated in the source; confirm them. Values are calculated from test flow, and the model-labelled curves are laboratory results, not unconditional delivered L/min. |
| Spannung und Vorsteuerspule | A AC220V; B DC24V; C AC110V; E AC24V; F DC12V. Size 0500 specifically uses CPSV10: A/B/C/F only, D DIN connector only. CPSV10 AC2VA/DC1W. The larger pilot-coil electrical row is CPSV15 with AC2VA/DC1.2W; confirm actual pilot-coil label when replacing separately. Do not transfer a 4V or 4STV spare-coil identity. |
| Elektrische Grenzen | AC allowance +15%/−10%; DC±10%. Published protection IP65 and insulation F apply to the pilot-coil electrical table; confirm the complete installed connector/sealing arrangement. No explosion-proof claim is made. |
| Stecker- und Leitungscode | Larger sizes: blank plug-in, I lead-out, D DIN connector, M M8 lead-out. Blank wire length 0.5 m or 200 length 2 m applies only to plug-in. I and M have fixed 0.5 m wires. No DIN cable-length selector is defined; lookup leaves DIN cable length for confirmation. Size 0500 restriction D overrides the general connection choices. |
| Gewicht und Montage | 0500 single/double 28/42 g; 100 63/89.5 g; 200101.5/129 g; 300196.5/227 g. Use correct single/double dimension table and size/port row. 6STV0510 and 0520 have no side S mounting holes; M5/06 drawings and P/Q/T ports must be read separately. |
| Basiscode und Quellenabweichung | Base ordering: 1F–30F, blankPT/G/T NPT; dimension tables 1F–20F. P-6STV[size]M-R2 blank-plate kit. Base kit includes base, gasket and screws; plate kit includes plate and screws. One base-ordering cell prints 6T300M while its specification, dimension and blank-plate rows print 6STV300M; confirm any 6T300M input rather than silently aliasing it. |
| Angaben zur Anfrage | Send full valve and pilot/electrical labels, required 3/2 function and initial state, operating pressure/flow, voltage and connector, wire length, inlet/outlet/exhaust thread, actual mounting and manifold stations, quantity and destination. Stock, lead time and installed fit are confirmed through inquiry. |