Pneumatic Model Confirmation & Multi-Brand BOM RFQs|Send the model, quantity and destination
Request a BOM Quote|
PneuPart.com
Industrial Pneumatics
Popular Sourcing Series
SDA Compact CylindersSC Standard Cylinders4V210 Solenoid ValvesAFR Filter RegulatorsPU Tubing (8mm / 6mm)Push-in FittingsZL Vacuum Generators
Fast-Track RFQ Services

BOM Parts List RFQ

Upload Excel spreadsheet or parts list for multi-item direct pricing

Photo & Label Matching

Send photo or nameplate of damaged parts for 1:1 replacement verification

WhatsAppQuote
Popular Sourcing Series
SDA Compact CylindersSC Standard Cylinders4V210 Solenoid ValvesAFR Filter RegulatorsPU Tubing (8mm / 6mm)Push-in FittingsZL Vacuum Generators
Fast-Track RFQ Services

BOM Parts List RFQ

Upload Excel spreadsheet or parts list for multi-item direct pricing

Photo & Label Matching

Send photo or nameplate of damaged parts for 1:1 replacement verification

Product Catalog
PneuPart Products
AirTAC Sourcing
Multi-brand Sourcing
Solutions
Start RFQ
Popular Series:
SCSDA4V210ACQPU Tube
Home/Product Series/AirTAC Sourcing/Fluid Control Valves/2KLA
AirTAC sourcing reference•Fluid Control Valves
SERIES2KLA

AirTAC 2KLA Normally Open Fluid Control Valves

2KLA direct product reference
Series product image
Request a QuoteWhatsAppSend a Photo — We’ll Help Identify It

The 2KLA family includes direct-acting 030/050 and internally piloted 150–500 normally open...

Official reference

Based on manufacturer documentation

Model support

For model confirmation

Parts lists

Code, photo, or BOM

Availability / lead time

By model and quantity

Sourcing route & inquiry details

The 2KLA family includes direct-acting 030/050 and internally piloted 150–500 normally open 2/2 valves with SUS304 bodies and PTFE seals. Match structure, pressure difference, medium, temperatures and complete model for a quotation.

Know your model? Send it with the quantity for a quote. Not sure? Start with a photo, label or description. We help identify the model and clarify availability and lead time. Mixed parts lists are welcome too.

Request type
AirTAC originalModel matchingChina-source alternative

Find your 2KLA type

Choose a type; send a model or photo if unsure.

2KLA030 / 050

Direct standard · max differential 0.7 MPa

2KLAH030 / 050

Direct H · max differential 1.5 MPa

2KLA150 / 200 / 250 / 320 / 400 / 500

Internally piloted · 0.05–0.7 MPa

View details →
Request a QuoteSend a Photo — We’ll Help Identify It →

Send the model, quantity and destination. For multiple items, attach a parts list or BOM.

Match a 2KLA model code

Drawings & dimensions

Installation Drawings & Technical Specifications

Compare installed dimensions
Full View
2KLA direct ordering referenceClick to open full drawing ↗

2KLA direct ordering reference

Helpful for Model Matching:

  • Full 2KLA valve and coil code or label
  • Direct or internal pilot; available inlet/outlet pressure difference
  • Steam, hot water or oil: exact temperature, viscosity and concentration
  • Port, thread, voltage, entry, mounting clearance, quantity and destination
  • Choose the exact direct or internally piloted body size.
  • Match terminal/grommet geometry, body flow direction and optional bracket scope.
  • Confirm pressure difference and media/ambient temperatures separately.

Catalogue Technical Specifications

AirTAC reference data
Actuation / stateDirect acting, normally open 2/2.
Differential / proof pressureStandard maximum differential 0.7 MPa; H maximum 1.5 MPa; proof 3 MPa. Minimum differential not specified.
Orifice / Cv / area030 standard: 3 mm/Cv 0.33/6 mm²; H: 2 mm/Cv 0.18/3 mm². 050 standard: 5 mm/Cv 0.83/15 mm²; H: 4 mm/Cv 0.55/10 mm².
Body / sealSUS304 stainless steel; fixed PTFE (Teflon) seal. No seal-choice code.
Fluid / ambient temperatureOil −10 to 150 °C; water 1 to 150 °C; steam maximum 183 °C, minimum not specified; ambient −20 to 100 °C. These are separate limits, not approval for every combined operating condition.
Viscosity caveatMain row under 20 cSt; oil footnote 50 cSt or less. Confirm the applicable oil requirement.
Coil / protectionValve pages specify Class H and IP65. AC50/60Hz ±15%, DC ±10%. Terminal blank, grommet I, wire length 0.5 m.
Coil selection / discrepanciesUse CDA110KH/CLA110KH for 030 and 150/200/250; CDA160KH/CLA160KH for 050 and 320/400/500. The K suffix denotes normally open, H denotes Class H. Page 196 gives a generic Class F table and different NO AC powers; confirm the actual coil label and power before replacement.
Temperature riseValve-page small coil: AC50Hz 50 °C, AC60Hz 45 °C, DC50 °C. Large coil: AC50Hz 65 °C, AC60Hz 60 °C, DC50 °C.
Published valve-page power030: AC50Hz 10 VA, AC60Hz 8 VA, DC7 W. 050: AC50Hz 25 VA, AC60Hz 22 VA, DC10.5 W. Generic NO coil page gives AC15/11 VA or 35/30 VA and DC6.5/12 W; confirm exact coil. The direct product photo shows 6.5 W, while its table gives 7 W for 030; check the original label.
Mounting accessories030: F-2WA030LB; 050: F-2WA050LB. Brackets are optional and separately specified, not included in the valve code.
Common Model Codes & Configurations:Useful for an RFQ
2KLA2KLA030-08-A2KLAH030-06-B-I-G2KLA050-15-F-T

Send the model code, quantity and destination, or attach a parts list.

WhatsAppQuote BOM
Technical reference & selection notes

Ordering Codes, Fit Verification & Specifications

Specifications, installation dimensions, and ordering-code notes.

Ordering code matching

Match each code segment

Send a photo if the code is incomplete

Code format

2KLA[blank/H][030/050]-[matching port]-[A/B/C/E/F]-[blank/I]-[blank/G/T]Published valve code; mounting accessories separate
CD/CL-[A110/A160]-K-[A/B/C/E/F]-HSeparate NO Class H coil: terminal CD or grommet CL; confirm label and power
2KLA030-08-A2KLAH030-06-B-I-G2KLA050-15-F-T
1Size / port2Voltage / entry / thread
Direct 030: 06/08; 050: 10/15. Pilot 150-15, 200-20, 250-25, 320-32, 400-40, 500-50. H applies only to direct 030/050.A=AC220V; B=DC24V; C=AC110V; E=AC24V; F=DC12V. Then optional I, then G/T (blank PT).

Avoid a wrong match

  • 2KLA is normally open; 2LA is normally closed. They are not the same fail-state replacement.
  • Direct standard/H maximum differential is 0.7/1.5 MPa; internal pilot needs 0.05–0.7 MPa.
  • 320 uses a 35 mm orifice, not 32 mm. H applies only to direct 030/050.
  • The valve pages and generic NO coil table disagree on power; Class F generic data does not override the Class H selection. Send the coil label.
  • Oil viscosity and pilot psi have source discrepancies. Confirm actual medium, temperatures and inlet/outlet pressures together.
  • IP65 is not explosion-proof certification; flow chart labels alone do not establish vacuum service.

Read the model code

If the label is incomplete, send the readable parts together with a photo.

2KLAH030-06-B-I-G

Size / portSize / port

Direct 030: 06/08; 050: 10/15. Pilot 150-15, 200-20, 250-25, 320-32, 400-40, 500-50. H applies only to direct 030/050.

Voltage / entry / threadVoltage / entry / thread

A=AC220V; B=DC24V; C=AC110V; E=AC24V; F=DC12V. Then optional I, then G/T (blank PT).

About 2KLA

2KLA includes two operating structures: direct-acting 030/050 with standard or H high-pressure configurations, and internally piloted 150/200/250/320/400/500 with a required 0.05–0.7 MPa pressure difference. Both are normally open with SUS304 bodies and PTFE seals. The technical workspace below covers the direct-acting range; use the linked internal-pilot page for its model-specific parameters and drawings.

Matching Questions

Is 2KLA a normally closed replacement?

No. 2KLA is normally open; its unpowered state differs from normally closed 2LA. Confirm the required fail state and the direct or internally piloted structure.

Which pressure and temperature limits apply?

Direct standard/H maximum differential is 0.7/1.5 MPa, proof 3 MPa. Internal pilot requires 0.05–0.7 MPa, proof 1.5 MPa. Oil −10 to 150 °C, water 1 to 150 °C, steam max 183 °C and ambient −20 to 100 °C are separate limits; submit actual conditions together.

Can I select a replacement coil from the generic table alone?

Use the NO K and Class H selection for 2KLA. Valve-page and generic NO power values differ; confirm the original coil label, voltage, entry and power. Send standalone coil codes for consultation.

2KLA

Include this series in a project RFQ

2KLA Add other models, quantities, photos, drawings, or a BOM. One request can cover several product groups.

Request a project quoteWhatsAppSend a parts list or BOM
Confirm inspection requirements before quotation•Specify shipping preference•Confirm timing in the quotation•Ocean & Rail Available

Pneupart

Pneupart is a China-based pneumatic sourcing brand for distributors, factories, and MRO buyers. Send a model, label, drawing or BOM for technical confirmation and quotation. Specify whether original AirTAC sourcing or an alternative is required.

Product Series

Cylinder SeriesSolenoid Valve SeriesQuick Connect FittingsAirTAC Sourcing

Company

About UsContact UsSupplier VerificationAlibaba.com ProfileAirTAC Partner Lookup

RFQ Support

SolutionsMulti-brand SourcingAirTAC Replacement

Contact

Email: [email protected]

WhatsApp: +86 177 0867 3949

Address: C701, 7th Floor, Building C, Shunyijia Intelligent Technology Park, No. 22 Huaxing Road, Zhangcha Street, Foshan, Guangdong, China

Quotation Notes:Include quantities, destination and requested delivery date in the RFQ.•Availability, shipping method, timing and trade terms are confirmed in the quotation.•Specify inspection and packaging requirements where they affect the request.
About PneupartPrivacyRFQ Terms

Pneupart is operated by Guangdong Wanjing Automation Technology Co., Ltd., Foshan, China.