Pneumatic Model Confirmation & Multi-Brand BOM RFQs|Send the model, quantity and destination
Request a BOM Quote|
PneuPart.com
Industrial Pneumatics
Popular Sourcing Series
SDA Compact CylindersSC Standard Cylinders4V210 Solenoid ValvesAFR Filter RegulatorsPU Tubing (8mm / 6mm)Push-in FittingsZL Vacuum Generators
Fast-Track RFQ Services

BOM Parts List RFQ

Upload Excel spreadsheet or parts list for multi-item direct pricing

Photo & Label Matching

Send photo or nameplate of damaged parts for 1:1 replacement verification

WhatsAppQuote
Popular Sourcing Series
SDA Compact CylindersSC Standard Cylinders4V210 Solenoid ValvesAFR Filter RegulatorsPU Tubing (8mm / 6mm)Push-in FittingsZL Vacuum Generators
Fast-Track RFQ Services

BOM Parts List RFQ

Upload Excel spreadsheet or parts list for multi-item direct pricing

Photo & Label Matching

Send photo or nameplate of damaged parts for 1:1 replacement verification

Product Catalog
PneuPart Products
AirTAC Sourcing
Multi-brand Sourcing
Solutions
Start RFQ
Popular Series:
SCSDA4V210ACQPU Tube
Home/Product Series/AirTAC Sourcing/Fluid Control Valves/2KSA Series/2KSA150 / 200 / 250 / 320 / 400 / 500
AirTAC sourcing reference•Fluid Control Valves
SERIES2KSA150 / 200 / 250 / 320 / 400 / 500

AirTAC 2KSA Internally Piloted Normally Open Valves

2KSA internally piloted normally open fluid valve product reference
Series product image
Request a QuoteWhatsAppSend a Photo — We’ll Help Identify It

Internally piloted 2/2 normally open valves with 15/20/25/35/40/50 mm orifices and a required...

Official reference

Based on manufacturer documentation

Model support

For model confirmation

Parts lists

Code, photo, or BOM

Availability / lead time

By model and quantity

Sourcing route & inquiry details

Internally piloted 2/2 normally open valves with 15/20/25/35/40/50 mm orifices and a required 0.05–0.7 MPa pressure differential. Send the full model, medium, pressures, quantity and destination for a quotation.

Know your model? Send it with the quantity for a quote. Not sure? Start with a photo, label or description. We help identify the model and clarify availability and lead time. Mixed parts lists are welcome too.

Match a 2KSA model code

Part of the 2KSA Series family.

View family overview →
Drawings & dimensions

Installation Drawings & Technical Specifications

Compare installed dimensions
Full View
2KSA internally piloted pressure differential, orifice, Cv and area specificationClick to open full drawing ↗

2KSA internally piloted pressure differential, orifice, Cv and area specification

Helpful for Model Matching:

  • Full 2KSA code, label or installed valve photo
  • Direct or internally piloted structure and inlet/outlet pressure
  • Medium, viscosity, fluid and ambient temperature
  • Port, PT/G/NPT thread, voltage and terminal/grommet entry
  • Mounting envelope or drawing
  • Quantity and destination; BOM accepted
  • Match direct or internally piloted construction
  • Match terminal or grommet drawing and the exact size row
  • Use operating pressure differential, not proof pressure
  • Send actual oil viscosity where the catalogue limits differ

Catalogue Technical Specifications

AirTAC reference data
Identity2/2, internally piloted, normally open
Operating pressure differential0.05–0.7 MPa; positive minimum differential required. The printed psi column (10–100) is inconsistent with MPa: use MPa for selection and confirm any psi requirement.
Proof pressure1.5 MPa (220 psi as printed); not operating pressure
150 / port / Cv / areaØ15 mm; 15=1/2; Cv 5.5; 100 mm²
200 / port / Cv / areaØ20 mm; 20=3/4; Cv 9.5; 170 mm²
250 / port / Cv / areaØ25 mm; 25=1; Cv 12.5; 220 mm²
320 / port / Cv / areaØ35 mm per specification and ordering table; 32=1 1/4; Cv 23.0; 420 mm². Water flow curve labels Φ32: confirm flow-critical requirements against the actual valve.
400 / port / Cv / areaØ40 mm; 40=1 1/2; Cv 31.0; 560 mm²
500 / port / Cv / areaØ50 mm; 50=2; Cv 49.0; 880 mm²
Coil / power150/200/250 CDA110K/CLA110K: AC 15 VA at 50 Hz, 11 VA at 60 Hz; DC 6.5 W. 320/400/500 CDA160K/CLA160K: AC 35 VA at 50 Hz, 30 VA at 60 Hz; DC 12 W
Medium / body / sealAir, water, oil; SUS304 stainless-steel body; standard FPM-F fluorine-rubber seal per English catalogue
Fluid and ambient temperatureWater 1–80°C; air −20–90°C; oil −10–80°C; direct ambient −20–70°C; internally piloted ambient −20–70°C
Air and oil conditionsAir dew point ≤−20°C. Viscosity row: under 20 cSt; oil footnote: ≤50 cSt. Actual oil requirement needs confirmation.
Coil / voltage toleranceClass F insulation; coil IP65; AC 50/60 Hz ±15%; DC ±10%
Common Model Codes & Configurations:Useful for an RFQ
2KSA150-15-A2KSA200-20-B-I-G2KSA250-25-C-T2KSA320-32-B-I-G

Send the model code, quantity and destination, or attach a parts list.

WhatsAppQuote BOM
Technical reference & selection notes

Ordering Codes, Fit Verification & Specifications

Specifications, installation dimensions, and ordering-code notes.

Ordering code matching

Match each code segment

Send a photo if the code is incomplete

Code format

2KSA[150/200/250/320/400/500]-[15/20/25/32/40/50]-[A/B/C/E/F]-[I if grommet]-[G/T if non-PT]Published valve code; mounting accessories are separate
2KSA150-15-A2KSA200-20-B-I-G2KSA250-25-C-T2KSA320-32-B-I-G2KSA400-40-A2KSA500-50-F-T
1Structure / size3Port4Voltage5Electrical entry6Thread
Direct 030/050; internally piloted 150/200/250/320/400/500. Both 2/2 normally open.030: 06=1/8, 08=1/4; 050: 10=3/8, 15=1/2. Pilot 150-15, 200-20, 250-25, 320-32, 400-40, 500-50.A AC220V; B DC24V; C AC110V; E AC24V; F DC12V.Blank terminal; I grommet, published lead length 0.5 m.Blank PT; G G; T NPT. Voltage precedes electrical entry and thread.

Quick check

Is this internally piloted 2KSA normally open?

Yes. It is normally open, like the direct-acting 2KSA. Its distinction is internal pilot operation, larger orifices and a required minimum pressure differential of 0.05 MPa.

2KSA150 / 200 / 250 / 320 / 400 / 500

Include this series in a project RFQ

2KSA150 / 200 / 250 / 320 / 400 / 500 Add other models, quantities, photos, drawings, or a BOM. One request can cover several product groups.

Request a project quoteWhatsAppSend a parts list or BOM
Confirm inspection requirements before quotation•Specify shipping preference•Confirm timing in the quotation•Ocean & Rail Available

Pneupart

Pneupart is a China-based pneumatic sourcing brand for distributors, factories, and MRO buyers. Send a model, label, drawing or BOM for technical confirmation and quotation. Specify whether original AirTAC sourcing or an alternative is required.

Product Series

Cylinder SeriesSolenoid Valve SeriesQuick Connect FittingsAirTAC Sourcing

Company

About UsContact UsSupplier VerificationAlibaba.com ProfileAirTAC Partner Lookup

RFQ Support

SolutionsMulti-brand SourcingAirTAC Replacement

Contact

Email: [email protected]

WhatsApp: +86 177 0867 3949

Address: C701, 7th Floor, Building C, Shunyijia Intelligent Technology Park, No. 22 Huaxing Road, Zhangcha Street, Foshan, Guangdong, China

Quotation Notes:Include quantities, destination and requested delivery date in the RFQ.•Availability, shipping method, timing and trade terms are confirmed in the quotation.•Specify inspection and packaging requirements where they affect the request.
About PneupartPrivacyRFQ Terms

Pneupart is operated by Guangdong Wanjing Automation Technology Co., Ltd., Foshan, China.