AirTAC 2LA Internally Piloted Normally Closed Valves

Internally piloted 2/2 valves with SUS304 bodies and PTFE seals. Required differential...
Official reference
Based on manufacturer documentation
Model support
For model confirmation
Parts lists
Code, photo, or BOM
Availability / lead time
By model and quantity
Sourcing route & inquiry details
Internally piloted 2/2 valves with SUS304 bodies and PTFE seals. Required differential pressure 0.05–0.7 MPa. Send model, medium, temperatures, pressures, quantity and destination.
Know your model? Send it with the quantity for a quote. Not sure? Start with a photo, label or description. We help identify the model and clarify availability and lead time. Mixed parts lists are welcome too.
Match a 2LA model code
Part of the 2LA Series family.
View family overview →Installation Drawings & Technical Specifications
2LA pilot ordering reference
Helpful for Model Matching:
- Full 2LA valve and coil code or label
- Direct or internal pilot; available inlet/outlet pressure difference
- Steam, hot water or oil: exact temperature, viscosity and concentration
- Port, thread, voltage, entry, mounting clearance, quantity and destination
- Choose the exact direct or internally piloted body size.
- Match terminal/grommet geometry, body flow direction and optional bracket scope.
- Confirm pressure difference and media/ambient temperatures separately.
Catalogue Technical Specifications
| Actuation / state | Internally piloted, normally closed 2/2. |
| Differential / proof pressure | Minimum 0.05 MPa, maximum 0.7 MPa, proof 1.5 MPa. Printed minimum 10 psi conflicts with 0.05MPa; confirm psi-specific requirements. |
| Orifice / Cv / area | 150: 15 mm/Cv 5.5/100 mm²; 200: 20/9.5/170; 250: 25/12.5/220; 320: 35/23/420; 400: 40/31/560; 500: 50/49/880. |
| Body / seal | SUS304 stainless steel; PTFE (Teflon) seal. No seal-choice code. |
| Fluid / ambient temperature | Oil −10 to 150 °C; water 1 to 150 °C; steam maximum 183 °C, minimum not specified; ambient −20 to 100 °C. |
| Viscosity caveat | Main row under 20 cSt; oil footnote 50 cSt or less. Confirm the applicable oil requirement. |
| Coil / protection | Class H; IP65; AC50/60Hz ±15%, DC±10%. Terminal blank, grommet I, wire 0.5 m. |
| Coil power | 030 and 150/200/250: AC50Hz 10VA, AC60Hz 8VA, DC6.5W. 050 and 320/400/500: AC50Hz 25VA, AC60Hz 22VA, DC12W. |
| Temperature rise | Small coil: AC50Hz 50 °C, AC60Hz 45 °C, DC50 °C. Large coil: AC50Hz 65 °C, AC60Hz 60 °C, DC50 °C. |
| Mounting / accessory scope | Optional brackets for 150–250; 320/400/500 have no mounting accessories. Source refers accessory details to 2WA P171, not included here. |
Ordering Codes, Fit Verification & Specifications
Ordering code matching
Match each code segment
Code format
2LA[150/200/250/320/400/500]-[matching port]-[A/B/C/E/F]-[blank/I]-[blank/G/T]Published valve code; mounting accessories separate2LA150-15-A2LA320-32-B-I-G2LA500-50-F-T| 1Size / port | 2Voltage / entry / thread |
|---|---|
| Direct 030: 06/08; 050: 10/15. Pilot 150-15, 200-20, 250-25, 320-32, 400-40, 500-50. H applies only to direct 030/050. | A=AC220V; B=DC24V; C=AC110V; E=AC24V; F=DC12V. Then optional I, then G/T (blank PT). |
Quick check
Which pressure differential applies to this model?
Direct standard/H maximum differential is 1/2 MPa respectively, with 3 MPa proof. Internal pilot requires 0.05–0.7 MPa, with 1.5 MPa proof. Send inlet and outlet pressures with the complete code.
Are steam or oil limits universal approval?
No. Confirm actual fluid, concentration, media and ambient temperatures. The viscosity row says under 20 cSt, while oil footnote says 50 cSt or less. The applicable oil requirement needs confirmation.
2LA150 / 200 / 250 / 320 / 400 / 500
Include this series in a project RFQ
2LA150 / 200 / 250 / 320 / 400 / 500 Add other models, quantities, photos, drawings, or a BOM. One request can cover several product groups.