Find your JCH type
Choose a type; send a model or photo if unsure.
JCH40
40 bore, 40 stroke, typeA dual pins
JCH63
63 bore, 40/60 stroke, typeB dual pins
Send the model, quantity and destination. For multiple items, attach a parts list or BOM.

JCH double-acting dual telescopic-pin cylinders use 40 mm/typeA or 63 mm/typeB...
Official reference
Based on manufacturer documentation
Model support
For model confirmation
Parts lists
Code, photo, or BOM
Availability / lead time
By model and quantity
JCH double-acting dual telescopic-pin cylinders use 40 mm/typeA or 63 mm/typeB configurations. Match published stroke, both pin interfaces, three-face mounting, PNP/NPN sensing and PT/G ports; send installed label and drawing for quotation.
Know your model? Send it with the quantity for a quote. Not sure? Start with a photo, label or description. We help identify the model and clarify availability and lead time. Mixed parts lists are welcome too.
Choose a type; send a model or photo if unsure.
JCH40
40 bore, 40 stroke, typeA dual pins
JCH63
63 bore, 40/60 stroke, typeB dual pins
Send the model, quantity and destination. For multiple items, attach a parts list or BOM.
Match a JCH Dual-Pin Code
AirTAC JCH specification
Helpful for Model Matching:
| Product identity | JCH is a double-acting dual telescopic-pin cylinder with two copper-bushing guide groups and a flat body. JCP single telescopic pin is a different family; no independent pin actuation, clamping force or safety-lock function is established by this source. |
| Published bore/stroke/pin types | 40 mm bore: 40 mm stroke, typeA.63 mm bore: 40/60 mm stroke, typeB. TypeA/B is tied to the published bore matrix, not a free choice on both bores.40×40 and 63×40/60 have distinct dimension references. |
| Source example conflict | The JCH ordering header shows JCH40X60AK, while the model matrix lists only a 40 mm stroke for bore 40 and the dimension drawing identifies JCH40X40. Confirm the 40×60 request against the original label and drawing. |
| Operating conditions | Operating pressure 0.3–0.8MPa; proof 1.2MPa not service pressure. Air filtered 40 μm or finer;−20 to 70°C. No maximum piston speed, load capacity or repeatability is published in this two-page sheet. |
| Sensor choices | Blank: no sensor; K: inductive proximity sensorPNP; KN: NPN. DIST-series sensing, not a reed-switch/magnetS ordering field. K/KN sensors may be purchased separately; confirm exact voltage, wiring, connector and quantity from actual sensor literature. |
| Pneumatic ports | 40 bore PT1/8; 63 bore PT1/4. Blank threadPT orG suffix forG thread. NoNPT/T published. Actual sensor interface and pipe thread are separate procurement fields. |
| Mounting and positioning | Three-face mounting is published. Match both pin-end interfaces, spacing, workpiece datum, mounting holes and clearance against the correct size drawing. Marked drawing pin-hole position tolerance±0.02 mm and screw-hole position±0.1 mm do not establish machine-level positioning repeatability. |
| Protection and construction | Source lists metal dust ring and scraper for two-stage weld-spatter protection, high-strength aluminum-alloy body and copper sliding bushings. An IP rating, seal immunity and unrestricted welding exposure are not specified. |
| Body weights | 40×40: 1.1 kg; 63×40: 4.5 kg; 63×60: 4.7 kg. The specification also lists 1.2 kg in the 40-bore 60-stroke weight row, which conflicts with the ordering/dimension matrix; do not use that row to validate 40×60 automatically. |
| RFQ inputs | Send fullJCH label, 40/63 bore and stroke, A/B pin type, sensorPNP/NPN or none, PT/G, both pin/mounting photos and workpiece drawing, quantity and destination. Confirm installed fit, load conditions and actual sensor/cable supply before replacement. |
Ordering code matching
Code format
JCH[40X40A/63X40B/63X60B][blank/K/KN][blank/G]40×60 configuration and JCP interchangeability require separate confirmationJCH40X40AJCH40X40AKJCH63X40BKGJCH63X60BKNG| 1Bore/stroke | 2Pin type | 3Sensor | 4Thread |
|---|---|---|---|
| 40×40 only; 63×40 or 63×60.40×60 code and dimensions require confirmation. | A for 40; B for 63. Match both pin interfaces. | Blank none; K inductivePNP; KN inductiveNPN. | BlankPT; G suffixG.40 ports 1/8; 63 ports 1/4. |
If the label is incomplete, send the readable parts together with a photo.
JCH40X40AK1Bore/stroke
40×40 only; 63×40 or 63×60.40×60 code and dimensions require confirmation.
2Pin type
A for 40; B for 63. Match both pin interfaces.
3Sensor
Blank none; K inductivePNP; KN inductiveNPN.
4Thread
BlankPT; G suffixG.40 ports 1/8; 63 ports 1/4.
JCH double-acting dual telescopic-pin cylinders use 40 mm/typeA or 63 mm/typeB configurations. Match published stroke, both pin interfaces, three-face mounting, PNP/NPN sensing and PT/G ports; send installed label and drawing for quotation.
The catalogue header and a weight row suggest 40×60, but the ordering matrix and drawing specify 40×40. Send the actual label/drawing for confirmation. JCH has dual telescopic pins; JCP single-pin construction is separate. Match both pin datums and installation before replacement.
JCH
JCH Add other models, quantities, photos, drawings, or a BOM. One request can cover several product groups.
Build your pneumatic circuit with complementary components. Confirm dimensions and operating conditions before selecting a combination.

Product-group reference image
Switch the pneumatic circuit. Select the valve function, flow capacity, port size and control signal for the application.

Product-group reference image
Control actuator air flow. Confirm thread, tube size, flow direction and required flow rate.

Product-group reference image
Connect tubing to a valve or actuator. Match tube outside diameter, port thread and seal type.

Product-group reference image
Run air lines between fittings and components. Confirm outside diameter, bend radius, pressure and temperature.
Send your parts list, connection sizes and operating conditions for a matching check and combined quotation.