Avoid a wrong match
- JCP single pin is not JCH twin-pin.
- No S magnet, arbitrary bore/stroke or NPT option.
- K PNP/KN NPN inductive, not a reed switch selector.
- Hole-position tolerance is not repeatability.
- No load/safety function inferred from model.

AirTAC JCP double-acting single retractable locating-pin assemblies, bore40/63 and...
Official reference
Based on manufacturer documentation
Model support
For model confirmation
Parts lists
Code, photo, or BOM
Availability / lead time
By model and quantity
AirTAC JCP double-acting single retractable locating-pin assemblies, bore40/63 and stroke40/60. Match own A/B/C/D pin geometry, DIST inductive sensor option, PT/G and fixture mounting before quotation.
Know your model? Send it with the quantity for a quote. Not sure? Start with a photo, label or description. We help identify the model and clarify availability and lead time. Mixed parts lists are welcome too.
AirTAC JCP specifications official Chinese reference
Helpful for Model Matching:
| Identity | JCP is a double-acting single retractable locating-pin assembly with two guide rods and adjustable limit screws, not a twin-pin JCH or a pin clamp like AQK. Bore40/63 mm and stroke40/60 mm are the complete published size matrix. |
| Conditions | Operating0.3–0.8 MPa; proof1.2 MPa separate. Filtered air40 μm or finer; −20 to70°C. No published load, repeatability or safety-function approval is inferred. |
| Pin types | Required pin A/B/C/D: each has its own top/side interface drawing and dimension/tolerance. A/B are different cross-hole/slot arrangements, C side profile, D plate pattern. Match own pin drawing, not just bore/stroke or a generic pin image. |
| Sensor | Blank no sensor; K inductive PNP, KN inductive NPN, DIST series. K/KN may be ordered separately. No magnetic S selector or reed switch inferred. Sensor cable, connector, supply and wiring details require exact selected-sensor confirmation. |
| Ports | Bore40 PT1/8;63 PT1/4. Blank PT, G suffix G thread. No NPT field. Two own air-port/mounting arrangements are shown in bore-specific drawings. |
| Mount and dimensional tolerance | Own bore40/63 drawings show four M8×1.25 mounting threads and Ø8 locating holes, with different body widths/envelopes. Published hole-position tolerance±0.02 and screw-hole position±0.1 refer to drawing dimensions marked with an asterisk. They are not positioning repeatability or complete assembly accuracy. |
| Envelope and weight | Total L240 mm at stroke40 and280 at stroke60 for both bores. Published weights:40 bore1.9/2.2 kg,63 bore2.9/3.4 kg at stroke40/60. Installed clearance, own pin type, sensor bracket and upper guide interface remain drawing confirmation. |
| RFQ inputs | Send full JCP code or readable label, pin A–D drawing and workpiece interface, bore/stroke, PT/G, K/KN wiring or sensorless need, mounting/clearance drawing, quantity and destination. Actual fixture fit, load and sensor supply confirmed on inquiry. |
Ordering code matching
Code format
JCP[40/63]X[40/60][A/B/C/D][blank/K/KN][blank/G]Single pin, required pin geometry, inductive sensor optional.JCP40X60AKJCP63X40DKNGJCP40X40B| 1Size and function | 2Pin | 3Sensor and ports |
|---|---|---|
| JCP is a double-acting single retractable locating-pin assembly with two guide rods and adjustable limit screws, not a twin-pin JCH or a pin clamp like AQK. Bore40/63 mm and stroke40/60 mm are the complete published size matrix. | Required pin A/B/C/D: each has its own top/side interface drawing and dimension/tolerance. A/B are different cross-hole/slot arrangements, C side profile, D plate pattern. Match own pin drawing, not just bore/stroke or a generic pin image. | Blank no sensor; K inductive PNP, KN inductive NPN, DIST series. K/KN may be ordered separately. No magnetic S selector or reed switch inferred. Sensor cable, connector, supply and wiring details require exact selected-sensor confirmation. Bore40 PT1/8;63 PT1/4. Blank PT, G suffix G thread. No NPT field. Two own air-port/mounting arrangements are shown in bore-specific drawings. |
If the label is incomplete, send the readable parts together with a photo.
JCP40X60AK1Size and function
JCP is a double-acting single retractable locating-pin assembly with two guide rods and adjustable limit screws, not a twin-pin JCH or a pin clamp like AQK. Bore40/63 mm and stroke40/60 mm are the complete published size matrix.
2Pin
Required pin A/B/C/D: each has its own top/side interface drawing and dimension/tolerance. A/B are different cross-hole/slot arrangements, C side profile, D plate pattern. Match own pin drawing, not just bore/stroke or a generic pin image.
3Sensor and ports
Blank no sensor; K inductive PNP, KN inductive NPN, DIST series. K/KN may be ordered separately. No magnetic S selector or reed switch inferred. Sensor cable, connector, supply and wiring details require exact selected-sensor confirmation. Bore40 PT1/8;63 PT1/4. Blank PT, G suffix G thread. No NPT field. Two own air-port/mounting arrangements are shown in bore-specific drawings.
AirTAC JCP double-acting single retractable locating-pin assemblies, bore40/63 and stroke40/60. Match own A/B/C/D pin geometry, DIST inductive sensor option, PT/G and fixture mounting before quotation.
No. JCP is the single retractable pin with its own pin A–D drawings, bore40/63 and stroke40/60. Published hole-position tolerances are drawing constraints, not repeatability. Send the exact pin and fixture drawing for confirmation.
JCP
JCP Add other models, quantities, photos, drawings, or a BOM. One request can cover several product groups.
Build your pneumatic circuit with complementary components. Confirm dimensions and operating conditions before selecting a combination.

Product-group reference image
Switch the pneumatic circuit. Select the valve function, flow capacity, port size and control signal for the application.

Product-group reference image
Control actuator air flow. Confirm thread, tube size, flow direction and required flow rate.

Product-group reference image
Connect tubing to a valve or actuator. Match tube outside diameter, port thread and seal type.

Product-group reference image
Run air lines between fittings and components. Confirm outside diameter, bend radius, pressure and temperature.
Send your parts list, connection sizes and operating conditions for a matching check and combined quotation.