Pneumatic Model Confirmation & Multi-Brand BOM RFQs|Send the model, quantity and destination
Request a BOM Quote|
PneuPart.com
Industrial Pneumatics
Popular Sourcing Series
SDA Compact CylindersSC Standard Cylinders4V210 Solenoid ValvesAFR Filter RegulatorsPU Tubing (8mm / 6mm)Push-in FittingsZL Vacuum Generators
Fast-Track RFQ Services

BOM Parts List RFQ

Upload Excel spreadsheet or parts list for multi-item direct pricing

Photo & Label Matching

Send photo or nameplate of damaged parts for 1:1 replacement verification

WhatsAppQuote
Popular Sourcing Series
SDA Compact CylindersSC Standard Cylinders4V210 Solenoid ValvesAFR Filter RegulatorsPU Tubing (8mm / 6mm)Push-in FittingsZL Vacuum Generators
Fast-Track RFQ Services

BOM Parts List RFQ

Upload Excel spreadsheet or parts list for multi-item direct pricing

Photo & Label Matching

Send photo or nameplate of damaged parts for 1:1 replacement verification

Product Catalog
PneuPart Products
AirTAC Sourcing
Multi-brand Sourcing
Solutions
Start RFQ
Popular Series:
SCSDA4V210ACQPU Tube
Home/Product Series/AirTAC Sourcing/Solenoid Valves/3V200
AirTAC sourcing reference•Solenoid Valves
SERIES3V200

AirTAC3V200 Three-Port Solenoid Valves

3V200 single-solenoid product reference
Series product image
Request a QuoteWhatsAppSend a Photo — We’ll Help Identify It

3/2 solenoid valves:3V210 single-solenoid NC/NO or3V220 double-solenoid with memory. Main...

Official reference

Based on manufacturer documentation

Model support

For model confirmation

Parts lists

Code, photo, or BOM

Availability / lead time

By model and quantity

Sourcing route & inquiry details

3/2 solenoid valves:3V210 single-solenoid NC/NO or3V220 double-solenoid with memory. Main ports1/8 or1/4. Send full model,quantity and destination for a quotation.

Know your model? Send it with the quantity for a quote. Not sure? Start with a photo, label or description. We help identify the model and clarify availability and lead time. Mixed parts lists are welcome too.

Request type
AirTAC originalModel matchingChina-source alternative

Find your 3V200 type

Choose a type; send a model or photo if unsure.

3V210-NC

Single solenoid ·normally closed

3V210-NO

Single solenoid ·normally open

3V220

Double solenoid ·memory function

Request a QuoteSend a Photo — We’ll Help Identify It →

Send the model, quantity and destination. For multiple items, attach a parts list or BOM.

Match a3V200 model code

Matching 3V manifold base

Choose 3V100M / 200M / 300M by valve size. Confirm valve model, stations, thread and assembly scope.

View base details and request a quote →
Drawings & dimensions

Installation Drawings & Technical Specifications

Compare installed dimensions
Full View
3V200 valve and coil ordering codeClick to open full drawing ↗

3V200 valve and coil ordering code

Helpful for Model Matching:

  • 3V210 single NC/NO or3V220 double with no NC/NO field
  • 06=1/8 or08=1/4;all three main ports same size
  • VoltageA/B/C/E/F;entry blank terminal orI grommet;then threadblank/G/T
  • Confirm internal/external pilot from installed valve,label or drawing
  • For manifold,confirm3V200M and station-specific installation clearance
  • Match3V210/3V220 and terminal/grommet drawing
  • Choose exact06/08 dimension row
  • Confirm internal/external pilot from installed valve and label

Catalogue Technical Specifications

AirTAC reference data
Function / pilot3 port2 position;internal or external pilot;3V210 single NC/NO;3V220 double with memory.
Main ports06:in/out/exhaust1/8;08:in/out/exhaust1/4. PT/G/NPT available.
Published flow area / Cv3V210-08 and3V220-08:17.0mm²/Cv1.0. No06 flow value given.
Operating / proof pressure0.15–0.8MPa(21–114psi);proof1.2MPa(175psi).
Temperature / body−20 to+70°C;aluminum alloy.
Medium / lubricationAir filtered by40μm element;lubrication not required. Once lubricated continue same medium;ISO VG32 or equivalent.
Voltage / powerAC220V4.5VA;AC110V4.5VA;AC24V5.0VA;DC24V3.0W;DC12V2.5W. AC tolerance±15%;DC±10%.
Coil / electrical entryIP65(DIN40050);B-class insulation;terminal or grommet;grommet lead0.5m.
Response / no-load frequencyActuating time0.05s or below;max5cycles/s(no load).
Common Model Codes & Configurations:Useful for an RFQ
3V2003V2103V2203V210-06-NC-A

Send the model code, quantity and destination, or attach a parts list.

WhatsAppQuote BOM
Technical reference & selection notes

Ordering Codes, Fit Verification & Specifications

Specifications, installation dimensions, and ordering-code notes.

Ordering code matching

Match each code segment

Send a photo if the code is incomplete

Code format

3V210-[06/08]-[NC/NO]-[A/B/C/E/F]-[blank/I]-[blank/G/T]Single solenoid
3V220-[06/08]-[A/B/C/E/F]-[blank/I]-[blank/G/T]Double solenoid;no NC/NO
3V210-06-NC-A3V210-08-NO-B-I-G3V220-08-F-T
①Circuit and port②Voltage③Entry then thread
10:single solenoid with NC/NO;20:double,no NC/NO. 06=1/8;08=1/4.A AC220V;B DC24V;C AC110V;E AC24V;F DC12V.Blank terminal;I grommet0.5m lead. Threadlast:blank PT,G G,T NPT. No pilot suffix shown.

Avoid a wrong match

  • Do not add NC/NO to3V220;do not omit it from3V210.
  • Do not swap DC24V(B) and AC24V(E).
  • Suffix order is acting type,voltage,electrical entry,thread. I means grommet,not external pilot.
  • Internal/external pilot is available but no pilot suffix is published;confirm the installed arrangement.
  • Use correct single/double and terminal/grommet drawing;06 and08 rows differ.

Read the model code

If the label is incomplete, send the readable parts together with a photo.

3V210-08-NO-B-I-G

3V2+10/20Valve size / circuit

200size;10single,20double.

06/08 +NC/NOPort and acting type

06=1/8;08=1/4;NC/NO single only.

A/B/C/E/FVoltage

AC220/DC24/AC110/AC24/DC12V.

blank/I thenblank/G/TElectrical entry and thread

Blank terminal;I grommet. Blank PT;G G;T NPT.

About 3V200

3V200 is one3/2 valve family. 10 single solenoid uses NC normally closed or NO normally open;20 double solenoid has memory and no NC/NO field. Internal or external pilot is available,but this sheet gives no pilot ordering suffix. Keep voltage,electrical entry and thread in that order.

Matching Questions

Do3V210 and3V220 use the same NC/NO code?

No. 3V210 single solenoid requires NC or NO;3V220 double solenoid has no such code and provides memory. Send the full label to avoid a wrong function.

Does I identify external pilot?

No. I is grommet electrical entry with0.5m lead. The catalogue allows internal or external pilot but does not publish a corresponding ordering suffix on this sheet;confirm from valve,label and installation.

What should I send for a valve assembly quotation?

Send full valve model,voltage,entry,thread,quantity and destination;for a base assembly add3V200M,station count,blank plates and installed clearance. Base and valve ports are separate fields.

3V200

Include this series in a project RFQ

3V200 Add other models, quantities, photos, drawings, or a BOM. One request can cover several product groups.

Request a project quoteWhatsAppSend a parts list or BOM
Confirm inspection requirements before quotation•Specify shipping preference•Confirm timing in the quotation•Ocean & Rail Available
COMPANION PRODUCTS

Products to use together

Build your pneumatic circuit with complementary components. Confirm dimensions and operating conditions before selecting a combination.

PneuPart tube fittings
Connect the air line

Product-group reference image

PneuPart tube fittings

Connect tubing to a valve or actuator. Match tube outside diameter, port thread and seal type.

View companion product
PneuPart pneumatic tubing
Route the air supply

Product-group reference image

PneuPart pneumatic tubing

Run air lines between fittings and components. Confirm outside diameter, bend radius, pressure and temperature.

View companion product
Air filters & regulators
Prepare the air supply

Product-group reference image

Air filters & regulators

Filter and regulate supply air. Confirm filtration, pressure range and flow requirements for the connected equipment.

View companion product

Planning a Complete Circuit or Multi-Item BOM?

Send your parts list, connection sizes and operating conditions for a matching check and combined quotation.

Submit Multi-Item Circuit RFQ

Pneupart

Pneupart is a China-based pneumatic sourcing brand for distributors, factories, and MRO buyers. Send a model, label, drawing or BOM for technical confirmation and quotation. Specify whether original AirTAC sourcing or an alternative is required.

Product Series

Cylinder SeriesSolenoid Valve SeriesQuick Connect FittingsAirTAC Sourcing

Company

About UsContact UsSupplier VerificationAlibaba.com ProfileAirTAC Partner Lookup

RFQ Support

SolutionsMulti-brand SourcingAirTAC Replacement

Contact

Email: [email protected]

WhatsApp: +86 177 0867 3949

Address: C701, 7th Floor, Building C, Shunyijia Intelligent Technology Park, No. 22 Huaxing Road, Zhangcha Street, Foshan, Guangdong, China

Quotation Notes:Include quantities, destination and requested delivery date in the RFQ.•Availability, shipping method, timing and trade terms are confirmed in the quotation.•Specify inspection and packaging requirements where they affect the request.
About PneupartPrivacyRFQ Terms

Pneupart is operated by Guangdong Wanjing Automation Technology Co., Ltd., Foshan, China.