Find your 3V3 type
Choose a type; send a model or photo if unsure.
3V308-NC
3/2 direct acting · normally closed
3V308-NO
3/2 direct acting · normally open
Send the model, quantity and destination. For multiple items, attach a parts list or BOM.

Direct-acting3V308 3/2 valves with1/4 ports and NC/NO selection. Match...
Official reference
Based on manufacturer documentation
Model support
For model confirmation
Parts lists
Code, photo, or BOM
Availability / lead time
By model and quantity
Direct-acting3V308 3/2 valves with1/4 ports and NC/NO selection. Match voltage,terminal/grommet entry andPT/G/NPT;send the full code,quantity and destination for a quotation.
Know your model? Send it with the quantity for a quote. Not sure? Start with a photo, label or description. We help identify the model and clarify availability and lead time. Mixed parts lists are welcome too.
Choose a type; send a model or photo if unsure.
3V308-NC
3/2 direct acting · normally closed
3V308-NO
3/2 direct acting · normally open
Send the model, quantity and destination. For multiple items, attach a parts list or BOM.
Match a 3V3 model code
3V308 ordering matrix NC/NO voltage entry and thread
Helpful for Model Matching:
| Function / port | 3-port2-position;direct acting;NC/NO;08=1/4;PT/G/NPT |
| Published orifice / Cv | 11mm²/Cv0.62 |
| Common operating pressure | 0–0.8MPa(0–114psi) |
| Vacuum application caveat | Vacuum use is published,but the vacuum row has inconsistent unit values. Confirm the required vacuum level and suitability before selection. |
| Proof pressure | 1.2MPa(175psi) |
| Temperature / body | −20 to+70°C;aluminum alloy |
| Coil voltage / tolerance | AC220V,AC110V,AC24V:±15%;DC24V,DC12V:±10% |
| Published coil power | AC:10VA;DC:6.5W |
| Coil protection / insulation | IP65(DIN40050);B Class;terminal or grommet |
| Response / frequency | 0.05s and below;maximum10cycles/s at no load |
| Medium / lubrication | Air filtered through40μm element;lubrication not required. |
Ordering code matching
Code format
3V308-[NC/NO]-[A/B/C/E/F][blank/I][blank/G/T]Direct-acting valve:state,voltage,entry,thread3V308-NC-B3V308-NO-BIG3V308-NC-AIT| 1Family / port | 2Normal state | 3Voltage | 4Electrical entry | 5Thread |
|---|---|---|---|---|
| Direct-acting3V3;08=1/4 only.No10/20 field. | NC normally closed;NO normally open. | A AC220V;B DC24V;C AC110V;E AC24V;F DC12V. | Blank terminal;I grommet,wire0.5m. | BlankPT;G G;T NPT;after entry. |
If the label is incomplete, send the readable parts together with a photo.
3V308-NO-BIG3V3+08Family / port
Direct-acting3V3;08=1/4 only.No10/20 field.
NC/NONormal state
NC normally closed;NO normally open.
A/B/C/E/FVoltage
A AC220V;B DC24V;C AC110V;E AC24V;F DC12V.
blank/IElectrical entry
Blank terminal;I grommet,wire0.5m.
blank/G/TThread
BlankPT;G G;T NPT;after entry.
3V3 is the direct-acting3V308 three-port,two-position solenoid valve,not the pilot-operated3V300 family. BothNC normally closed andNO normally open are published;only08=1/4 port size is shown. Common-pressure operation starts at0MPa. Vacuum use is mentioned,but the source vacuum row contains inconsistent unit values:confirm the application rather than assuming a numerical vacuum rating.
No.3V3 uses direct-acting3V308 withNC/NO and1/4 ports.The code has no10/20 pilot-arrangement field.Use its own installation drawings and coil specifications.
Yes.Send the original code,label or photo,required vacuum level,quantity and destination.Vacuum use is listed but its numerical pressure row is inconsistent,so suitability must be confirmed for your application.
3V3
3V3 Add other models, quantities, photos, drawings, or a BOM. One request can cover several product groups.
Build your pneumatic circuit with complementary components. Confirm dimensions and operating conditions before selecting a combination.

Product-group reference image
Connect tubing to a valve or actuator. Match tube outside diameter, port thread and seal type.

Product-group reference image
Run air lines between fittings and components. Confirm outside diameter, bend radius, pressure and temperature.

Product-group reference image
Filter and regulate supply air. Confirm filtration, pressure range and flow requirements for the connected equipment.
Send your parts list, connection sizes and operating conditions for a matching check and combined quotation.