Find your 4M type
Choose a type; send a model or photo if unsure.
4M
NAMUR 5/2, single/double solenoid
Send the model, quantity and destination. For multiple items, attach a parts list or BOM.

4M NAMUR 5/2 valves 100/200/300 for actuator-side mounting. Match single/double solenoid,...
Official reference
Based on manufacturer documentation
Model support
For model confirmation
Parts lists
Code, photo, or BOM
Availability / lead time
By model and quantity
4M NAMUR 5/2 valves 100/200/300 for actuator-side mounting. Match single/double solenoid, port, coil voltage, terminal/grommet and thread; send actuator interface, quantity and destination for quotation.
Know your model? Send it with the quantity for a quote. Not sure? Start with a photo, label or description. We help identify the model and clarify availability and lead time. Mixed parts lists are welcome too.
Choose a type; send a model or photo if unsure.
4M
NAMUR 5/2, single/double solenoid
Send the model, quantity and destination. For multiple items, attach a parts list or BOM.
Match a 4M NAMUR Valve
AirTAC 4M official English 4m official specification
Helpful for Model Matching:
| Family / control scope | 4M is a NAMUR 5/2 internally piloted solenoid valve family 100/200/300. Code10 single solenoid with spring-return symbol; 20 double solenoid with memory function. No5/3 center-state, 30/40 valve type, 400 size or FB explosion-proof configuration is published in this source. Single/double and sizes remain selection fields in one family, not thin child URLs. |
| Published models / ports | 100: 4M110/120-M5 or-06; 200: 4M210/220-06 or-08; 300: 4M310/320-08 or-10. M5 inlet/exhaust M5 with no thread-type code.06 inlet1/8; 200-08 inlet1/4 with exhaust1/8; 300-08 inlet1/4, 300-10 inlet3/8 with exhaust1/4. Blank PT, G suffixG, NPT suffixT for inch ports. The SCF PT/G-only ordering format does not apply to standalone 4M valves. |
| Pressure / air / temperature | Air filtered by40µm element; internal pilot, operating0.15–0.8MPa, proof1.2MPa, −20 to70°C. Proof is not allowed operation; minimum pilot pressure matters. Aluminium-alloy body. Lubrication not required; once lubricated, continue same medium, ISO VG32 or equivalent source recommendation. |
| Electrical ordering | A AC220V, B DC24V, C AC110V, E AC24V, F DC12V. Blank terminal, I grommet with0.5m wire. AC tolerance±15%, DC±10%; B insulation; IP65(DIN40050) coil specification. Correct connector installation/application needs confirmation; not explosion-proof certification or unlimited environment guarantee. |
| Coil power by family and voltage | 4M110/120 AC220/110=3.5VA, AC24=4.0VA, DC24=2.8W, DC12=2.5W.4M210/220/310/320 AC220/110=4.5VA, AC24=5.0VA, DC24=3.0W, DC12=2.5W. Do not use a universal3W or confuse VA with W. |
| Frequency / switching time / flow | 100/200 max5cycles/s, 300max4cycles/s, explicitly no-load; activation≤0.05s. Not actuator complete-stroke cycle or safety stopping time. Published reference orifice/Cv only100-06=10.2mm²/0.6, 200-08=17.0/1.0, 300-10=28.0/1.65. NoM5/200-06/300-08 flow number inferred; source refers equivalent4V types for flow charts, not4V product identity or mounting compatibility. |
| NAMUR installation / drawings | Source directs mounting at actuator side plate, with surface upward, directly connecting actuators. Own dimensional drawings cover110/120/210/220/310/320 separately for terminal and grommet. Size-dependent ports, hole spacing, screws, manual override and length must use the exact drawing. No ordinary4V manifold or published4M sub-base family is inferred; send actuator interface/seal/bolt drawing for confirmation. |
| Supply scope / memory boundary | Quote the standalone complete valve with selected electrical entry, not an SCF cylinder-plus-valve assembly. Source says double-solenoid memory, not a certified fail-safe holding function. Confirm required de-energised behavior, air-loss behavior, manual override use and actual pneumatic circuit. NoATEX/IECEx claim added. |
Ordering code matching
Code format
4M[1/2/3][10/20]-[M5/06/08/10][A/B/C/E/F][I][G/T]Exact size/port pair; M5 has no thread suffix4M310-10A4M220-08BIG4M110-M5F| 1Size / control | 2Port / thread | 3Voltage / entry |
|---|---|---|
| 4M is a NAMUR 5/2 internally piloted solenoid valve family 100/200/300. Code10 single solenoid with spring-return symbol; 20 double solenoid with memory function. No5/3 center-state, 30/40 valve type, 400 size or FB explosion-proof configuration is published in this source. Single/double and sizes remain selection fields in one family, not thin child URLs. | 100: 4M110/120-M5 or-06; 200: 4M210/220-06 or-08; 300: 4M310/320-08 or-10. M5 inlet/exhaust M5 with no thread-type code.06 inlet1/8; 200-08 inlet1/4 with exhaust1/8; 300-08 inlet1/4, 300-10 inlet3/8 with exhaust1/4. Blank PT, G suffixG, NPT suffixT for inch ports. The SCF PT/G-only ordering format does not apply to standalone 4M valves. | A AC220V, B DC24V, C AC110V, E AC24V, F DC12V. Blank terminal, I grommet with0.5m wire. AC tolerance±15%, DC±10%; B insulation; IP65(DIN40050) coil specification. Correct connector installation/application needs confirmation; not explosion-proof certification or unlimited environment guarantee. |
If the label is incomplete, send the readable parts together with a photo.
4M310-10A1Size / control
4M is a NAMUR 5/2 internally piloted solenoid valve family 100/200/300. Code10 single solenoid with spring-return symbol; 20 double solenoid with memory function. No5/3 center-state, 30/40 valve type, 400 size or FB explosion-proof configuration is published in this source. Single/double and sizes remain selection fields in one family, not thin child URLs.
2Port / thread
100: 4M110/120-M5 or-06; 200: 4M210/220-06 or-08; 300: 4M310/320-08 or-10. M5 inlet/exhaust M5 with no thread-type code.06 inlet1/8; 200-08 inlet1/4 with exhaust1/8; 300-08 inlet1/4, 300-10 inlet3/8 with exhaust1/4. Blank PT, G suffixG, NPT suffixT for inch ports. The SCF PT/G-only ordering format does not apply to standalone 4M valves.
3Voltage / entry
A AC220V, B DC24V, C AC110V, E AC24V, F DC12V. Blank terminal, I grommet with0.5m wire. AC tolerance±15%, DC±10%; B insulation; IP65(DIN40050) coil specification. Correct connector installation/application needs confirmation; not explosion-proof certification or unlimited environment guarantee.
4M NAMUR 5/2 valves 100/200/300 for actuator-side mounting. Match single/double solenoid, port, coil voltage, terminal/grommet and thread; send actuator interface, quantity and destination for quotation.
4M is a NAMUR 5/2 internally piloted solenoid valve family 100/200/300. Code10 single solenoid with spring-return symbol; 20 double solenoid with memory function. No5/3 center-state, 30/40 valve type, 400 size or FB explosion-proof configuration is published in this source. Single/double and sizes remain selection fields in one family, not thin child URLs. Source directs mounting at actuator side plate, with surface upward, directly connecting actuators. Own dimensional drawings cover110/120/210/220/310/320 separately for terminal and grommet. Size-dependent ports, hole spacing, screws, manual override and length must use the exact drawing. No ordinary4V manifold or published4M sub-base family is inferred; send actuator interface/seal/bolt drawing for confirmation.
Quote the standalone complete valve with selected electrical entry, not an SCF cylinder-plus-valve assembly. Source says double-solenoid memory, not a certified fail-safe holding function. Confirm required de-energised behavior, air-loss behavior, manual override use and actual pneumatic circuit. NoATEX/IECEx claim added.
4M
4M Add other models, quantities, photos, drawings, or a BOM. One request can cover several product groups.
Build your pneumatic circuit with complementary components. Confirm dimensions and operating conditions before selecting a combination.

Product-group reference image
Connect tubing to a valve or actuator. Match tube outside diameter, port thread and seal type.

Product-group reference image
Run air lines between fittings and components. Confirm outside diameter, bend radius, pressure and temperature.

Product-group reference image
Filter and regulate supply air. Confirm filtration, pressure range and flow requirements for the connected equipment.
Send your parts list, connection sizes and operating conditions for a matching check and combined quotation.