| Catalogue scope | Official Chinese catalogue, printed 97–99. 5V sizes 100/200/300/400 and single/double/three-position circuit options are covered; match the complete valve and electrical code before quotation. |
| Function and pilot | 10 single-solenoid 5/2; 20 double-solenoid 5/2; 30C double-solenoid 5/3 closed center; 30E exhaust center; 30P pressure center. Internal pilot only is published here, unlike the 4V internal/external-pilot table. Confirm actual circuit and center behavior; no certified safety-stop or load-holding guarantee. |
| Pressure, media and temperature | Operating 0.15–0.8 MPa; proof 1.2 MPa is not service pressure. Air filtered to 40 μm or finer; −10 to 50°C; aluminum alloy body. Lubrication not required. Continue lubrication without interruption once used; ISO VG32 or equivalent recommended. |
| Size/port matrix | 100 M5: inlet/outlet/exhaust M5; 100 06: all PT1/8. 200 06: all PT1/8; 200 08: inlet/outlet PT1/4, exhaust PT1/8. 300 08: all PT1/4; 300 10: inlet/outlet PT3/8, exhaust PT1/4. 400 15: all PT1/2. |
| Thread limits | Ordering table publishes blank PT for inch ports and no thread code for M5. The specification footnote also lists PT only. No G or NPT option is inferred from 4V or a manifold accessory; requests for other threads require technical confirmation. |
| Voltage and electrical ratings | A AC220V; B DC24V; C AC110V; E AC24V; F DC12V. AC allowance +15% / −10%; DC ±10%. All three AC voltages 2.0VA; both DC voltages 1.6W. Protection is dust protection, with no numeric IP rating; insulation class F, not 4V class B/IP65. |
| Terminal wiring and required code | Electrical connection is terminal type. Required terminal wire-length code 050 = 0.5m, 200 = 2m. Vertical and parallel terminal arrangements use the same wiring terminal according to the installation page; confirm actual orientation and installed clearance. No I grommet/blank-terminal field from 4V is added. |
| Flow scope 100 / 200 | 100: 5V110-06/120-06 equivalent area 10.2mm², Cv0.6; 5V130C-06 8.6mm², Cv0.51. 200: 5V210-08/220-08 17mm², Cv1; 5V230C-08 13.6mm², Cv0.8. Unlisted M5/06 and E/P values are not inherited. |
| Flow scope 300 / 400 | 300: 5V310-10/320-10 equivalent area 31.5mm², Cv1.85; 5V330C-10 23mm², Cv1.35. These differ from 4V300 ratings and must not be copied. 400: 5V410-15/420-15 48mm², Cv2.82; 5V430C-15 40mm², Cv2.35. Unlisted 08 or E/P values require confirmation. Curves are model-labelled AirTAC laboratory results, not unconditional L/min promises. |
| Weights | 100: 120/175/200g; 200: 220/320/360g; 300: 310/400/450g; 400: 590/720/770g, respectively single 5/2 / double 5/2 / three-position. Do not use a common weight across sizes. |
| Drawings and base | Printed page 99 has separate single, double and three-position dimension tables for all supported size/port combinations. Exact length, mounting holes, port pitch and terminal envelope differ. Dedicated 4V/5V manifold/base is a separate linked accessory: family, station count, thread, blank plates and mounting must be confirmed independently. |
| Installation and RFQ inputs | Installation page illustrates pilot and manual override, push/rotary locking behavior, and terminal orientations. Confirm that manual override cannot move connected equipment dangerously before use. Send full valve/electrical code or label, circuit, pilot/supply pressure, required flow, terminal wire length/orientation, actual thread/base and mounting dimensions, quantity and destination for quotation. |