Find your 6SV type
Choose a type; send a model or photo if unsure.
6SV
5/2 and 5/3 slim-body valves
Send the model, quantity and destination. For multiple items, attach a parts list or BOM.

6SV slim-body 5/2 and 5/3 valves, sizes 0500–400. Match control or center state, voltage,...
Official reference
Based on manufacturer documentation
Model support
For model confirmation
Parts lists
Code, photo, or BOM
Availability / lead time
By model and quantity
6SV slim-body 5/2 and 5/3 valves, sizes 0500–400. Match control or center state, voltage, electrical entry, wire length and ports; send label, quantity and destination for quotation.
Know your model? Send it with the quantity for a quote. Not sure? Start with a photo, label or description. We help identify the model and clarify availability and lead time. Mixed parts lists are welcome too.
Choose a type; send a model or photo if unsure.
6SV
5/2 and 5/3 slim-body valves
Send the model, quantity and destination. For multiple items, attach a parts list or BOM.
Match a 6SV Valve and Electrical Entry
Choose the base by valve size. Confirm stations, thread, blank plates and supply scope. Check installed dimensions and electrical clearance for the actual valve assembly.
View base details and request a quote →The source identifies CPSV15 for sizes 100 and larger. Size 0500 uses CPSV10. Confirm both valve labels, electrical form and interface before replacement.
View CPSV15 and request confirmation →AirTAC 6SV 6sv specification official reference
Helpful for Model Matching:
| Family and model identity | 6SV internally piloted slim-body solenoid valves: 0500/100/200/300/400 series. Smallest actual valve prefix is 6SV0510/0520/0530, not 6SV05010. 10 single-solenoid 5/2; 20 double-solenoid 5/2; 30C closed-center, 30E exhaust-center, 30P pressure-center dual-solenoid 5/3. Ordinary actions, ports and voltage remain one-family selection fields. |
| Published ports and thread | 0500 M5 only; 100 M5 or 06=1/8; 200 06=1/8 or 08=1/4; 300 10=3/8; 400 15=1/2. Main ports P/A/B share selected size; R/S exhaust 0500=M5, 100=M5 or1/8 by port, 200=1/8, 300=1/4, 400=1/2. Inch ports blank PT, G or T=NPT. Metric M5 has no thread suffix. |
| Pressure and operating conditions | 5/3 minimum pressure 0.2 MPa; other 5/2 0.15 MPa; maximum 0.8 MPa. Proof 1.2 MPa is not operating pressure. −20 to 70°C, air filtered through 40µm or finer, aluminium alloy body. No external-pilot ordering option inferred. |
| Coil and voltage boundary | 0500 uses CPSV10: AC220V/AC110V/DC24V/DC12V, no AC24V. 100–400 CPSV15 adds AC24V. Voltage codes A AC220V, B DC24V, C AC110V, E AC24V, F DC12V. Coils are not specified as interchangeable across all sizes. CPSV10 AC2.0VA/DC1W; CPSV15 AC2.0VA/DC1.2W. AC +15%/−10%, DC±10%; IP65, F insulation, excitation≤0.05s are source electrical conditions. |
| Entry and cable length | Blank plug terminal can be installed horizontally or vertically; I lead wire; D DIN connector; M M8 lead. 0500 has no DIN option. Plug wire length blank 0.5m or code 200=2m; I/M fixed 0.5m, no 200 length suffix. Do not confuse code 200 with valve size. |
| Valve frequency and flow | Maximum unloaded row explicitly maps 0500/100: 10/20 5/s, 30C/E/P 3/s; 200/300/400 not clearly mapped in this row, so frequency remains unconfirmed. Not complete actuator stroke cycle. Published equivalent area/Cv examples: 0500 M5 10/20=4.25mm²/0.25, 30C=3.7/0.2; 100-06 10/20=12.3/0.7, 30C=10/0.5; 200-08=17.9/1.05, 30C16.2/0.9; 300-10=38.4/2.25, 30C30.5/1.8; 400-15=57.6/3.2, 30C54.1/3. Source curves are laboratory test values for 0510-M5/110-06/210-08/310-10/410-15, not guaranteed flow at arbitrary pressure or E/P center equivalents. |
| Exhaust and lubrication | Internal exhaust collects pilot air and discharges through main R/S exhaust. Not a separately published pilot-exhaust fitting. Lubrication not required; if lubricated do not stop, source suggests ISO VG32 or equivalent. Muffler/exhaust routing/back-pressure need actual circuit confirmation. |
| Mounting and manual override | Own source single/double/5/3 tables distinguish size, port and length; use actual row and connector clearance, not 4SV/4V dimensions. Manual override only with complete circuit confirmation. Source mounting torque 0500 0.10–0.12N·m with M1.6×14; 100–400 0.4–0.45N·m with M2.5×17; lock manual override uses 2 mm screwdriver0.1N·m. Do not substitute generic bolt torque. |
| Matching base and supply scope | Source matching 6SV0500M/100M/200M/300M/400M correspond 6SV0500/100/200/300/400. Base ordering 1F–30F, dimensions 1F–20F; >20 requires complete installation drawing. Blank PT/G/T. P-6SV[model]M-R2 blank plate; base kit base/seals/screws, plate kit plate/screws. Standalone valve does not include base or plates automatically. Retain existing independent 6SV base route shared with separately sourced6SA pairing; no duplicate base page. |
Ordering code matching
Code format
6SV[05/1/2/3/4][10/20/30C/30E/30P]-[port][A/B/C/E/F][I/D/M][200][G/T]Use size-specific port, voltage, entry and cable restrictions6SV210-08B6SV230C-08BI6SV0510-M5B6SV110-06B200G| 1Family and model identity | 2Published ports and thread | 3Pressure and operating conditions | 4Coil and voltage boundary | 5Entry and cable length |
|---|---|---|---|---|
| 6SV internally piloted slim-body solenoid valves: 0500/100/200/300/400 series. Smallest actual valve prefix is 6SV0510/0520/0530, not 6SV05010. 10 single-solenoid 5/2; 20 double-solenoid 5/2; 30C closed-center, 30E exhaust-center, 30P pressure-center dual-solenoid 5/3. Ordinary actions, ports and voltage remain one-family selection fields. | 0500 M5 only; 100 M5 or 06=1/8; 200 06=1/8 or 08=1/4; 300 10=3/8; 400 15=1/2. Main ports P/A/B share selected size; R/S exhaust 0500=M5, 100=M5 or1/8 by port, 200=1/8, 300=1/4, 400=1/2. Inch ports blank PT, G or T=NPT. Metric M5 has no thread suffix. | 5/3 minimum pressure 0.2 MPa; other 5/2 0.15 MPa; maximum 0.8 MPa. Proof 1.2 MPa is not operating pressure. −20 to 70°C, air filtered through 40µm or finer, aluminium alloy body. No external-pilot ordering option inferred. | 0500 uses CPSV10: AC220V/AC110V/DC24V/DC12V, no AC24V. 100–400 CPSV15 adds AC24V. Voltage codes A AC220V, B DC24V, C AC110V, E AC24V, F DC12V. Coils are not specified as interchangeable across all sizes. CPSV10 AC2.0VA/DC1W; CPSV15 AC2.0VA/DC1.2W. AC +15%/−10%, DC±10%; IP65, F insulation, excitation≤0.05s are source electrical conditions. | Blank plug terminal can be installed horizontally or vertically; I lead wire; D DIN connector; M M8 lead. 0500 has no DIN option. Plug wire length blank 0.5m or code 200=2m; I/M fixed 0.5m, no 200 length suffix. Do not confuse code 200 with valve size. |
If the label is incomplete, send the readable parts together with a photo.
6SV210-08B1Family and model identity
6SV internally piloted slim-body solenoid valves: 0500/100/200/300/400 series. Smallest actual valve prefix is 6SV0510/0520/0530, not 6SV05010. 10 single-solenoid 5/2; 20 double-solenoid 5/2; 30C closed-center, 30E exhaust-center, 30P pressure-center dual-solenoid 5/3. Ordinary actions, ports and voltage remain one-family selection fields.
2Published ports and thread
0500 M5 only; 100 M5 or 06=1/8; 200 06=1/8 or 08=1/4; 300 10=3/8; 400 15=1/2. Main ports P/A/B share selected size; R/S exhaust 0500=M5, 100=M5 or1/8 by port, 200=1/8, 300=1/4, 400=1/2. Inch ports blank PT, G or T=NPT. Metric M5 has no thread suffix.
3Pressure and operating conditions
5/3 minimum pressure 0.2 MPa; other 5/2 0.15 MPa; maximum 0.8 MPa. Proof 1.2 MPa is not operating pressure. −20 to 70°C, air filtered through 40µm or finer, aluminium alloy body. No external-pilot ordering option inferred.
4Coil and voltage boundary
0500 uses CPSV10: AC220V/AC110V/DC24V/DC12V, no AC24V. 100–400 CPSV15 adds AC24V. Voltage codes A AC220V, B DC24V, C AC110V, E AC24V, F DC12V. Coils are not specified as interchangeable across all sizes. CPSV10 AC2.0VA/DC1W; CPSV15 AC2.0VA/DC1.2W. AC +15%/−10%, DC±10%; IP65, F insulation, excitation≤0.05s are source electrical conditions.
5Entry and cable length
Blank plug terminal can be installed horizontally or vertically; I lead wire; D DIN connector; M M8 lead. 0500 has no DIN option. Plug wire length blank 0.5m or code 200=2m; I/M fixed 0.5m, no 200 length suffix. Do not confuse code 200 with valve size.
6SV slim-body 5/2 and 5/3 valves, sizes 0500–400. Match control or center state, voltage, electrical entry, wire length and ports; send label, quantity and destination for quotation.
0500 uses CPSV10: AC220V/AC110V/DC24V/DC12V, no AC24V. 100–400 CPSV15 adds AC24V. Voltage codes A AC220V, B DC24V, C AC110V, E AC24V, F DC12V. Coils are not specified as interchangeable across all sizes. CPSV10 AC2.0VA/DC1W; CPSV15 AC2.0VA/DC1.2W. AC +15%/−10%, DC±10%; IP65, F insulation, excitation≤0.05s are source electrical conditions. Blank plug terminal can be installed horizontally or vertically; I lead wire; D DIN connector; M M8 lead. 0500 has no DIN option. Plug wire length blank 0.5m or code 200=2m; I/M fixed 0.5m, no 200 length suffix. Do not confuse code 200 with valve size.
Source matching 6SV0500M/100M/200M/300M/400M correspond 6SV0500/100/200/300/400. Base ordering 1F–30F, dimensions 1F–20F; >20 requires complete installation drawing. Blank PT/G/T. P-6SV[model]M-R2 blank plate; base kit base/seals/screws, plate kit plate/screws. Standalone valve does not include base or plates automatically. Retain existing independent 6SV base route shared with separately sourced6SA pairing; no duplicate base page.
6SV
6SV Add other models, quantities, photos, drawings, or a BOM. One request can cover several product groups.
Build your pneumatic circuit with complementary components. Confirm dimensions and operating conditions before selecting a combination.

Product-group reference image
Connect tubing to a valve or actuator. Match tube outside diameter, port thread and seal type.

Product-group reference image
Run air lines between fittings and components. Confirm outside diameter, bend radius, pressure and temperature.

Product-group reference image
Filter and regulate supply air. Confirm filtration, pressure range and flow requirements for the connected equipment.
Send your parts list, connection sizes and operating conditions for a matching check and combined quotation.