Avoid a wrong match
- 0500 has no AC24V or DIN terminal.
- 200/300 exhaust is smaller than main ports.
- 30E/P flow and 200/300 frequency require confirmation.
- Manifold and 7SA are independent products, not valve variants.

AirTAC 7SV 5/2 and 5/3 solenoid valves in 0500/100/200/300 sizes. Confirm 10/20 or 30C/E/P...
Official reference
Based on manufacturer documentation
Model support
For model confirmation
Parts lists
Code, photo, or BOM
Availability / lead time
By model and quantity
AirTAC 7SV 5/2 and 5/3 solenoid valves in 0500/100/200/300 sizes. Confirm 10/20 or 30C/E/P control, main/exhaust ports, voltage, connector and wire length. 0500 excludes AC24V and DIN terminal. Send the code, label or circuit with quantity and destination for quotation.
Know your model? Send it with the quantity for a quote. Not sure? Start with a photo, label or description. We help identify the model and clarify availability and lead time. Mixed parts lists are welcome too.
Match a 7SV solenoid valve
Choose the base by valve size. Confirm stations, thread, blank plates and supply scope. Check installed dimensions and electrical clearance for the actual valve assembly.
View base details and request a quote →The source identifies CPSV15 for sizes 100 and larger. Size 0500 uses CPSV10. Confirm both valve labels, electrical form and interface before replacement.
View CPSV15 and request confirmation →AirTAC 7SV official symbols
Helpful for Model Matching:
| Size / main and exhaust ports | 0500 code05 M5×0.8 all ports; 100 code1 port06=1/8 all ports; 200 code2 port08=1/4 main with 1/8 exhaust; 300 code3 port10=3/8 main with 1/4 exhaust. No alternative port sizes or 400 in this source. |
| Control / center | 10 single-solenoid 5/2; 20 double-solenoid 5/2; 30C double 5/3 closed center, 30E exhaust center, 30P pressure center. No NC/NO field. Actual pneumatic symbol and deenergized behavior need machine-circuit confirmation; center/double control is not certified safety holding. |
| Pressure / air / temperature | 5/2 working 0.15–0.8MPa; 5/3 working 0.2–0.8MPa; proof 1.2MPa is not service pressure. Air filtered to 40μm or finer; −20–70°C; aluminium alloy. Lubrication not required; once lubricated, use same medium, ISO VG32 or equivalent. |
| Pilot coil / electrical supply | 0500 adopts CPSV10: A AC220V, B DC24V, C AC110V, F DC12V; no E AC24V. AC 2.0VA / DC 1.0W. 100/200/300 adopts CPSV15:A/B/C/E/F including AC24V; AC 2.0VA / DC 1.2W. Source explicitly names pilot valves, not a universal replacement-coil kit or 080/092 compatibility. |
| Entry / wire / thread | 0500 blank terminal/I grommet/M M8; no D DIN. Other sizes blank terminal/I/D DIN/M M8. Terminal wire 0.5m blank or200=2m; grommet/M8 remain 0.5m. DIN 200 insufficiently clear, confirm. 0500 M5 no thread suffix; others blank PT/G G/T NPT. |
| Coil conditions / duty | AC+15%/−10%, DC±10%; F insulation; IP65; activation≤0.05s. Frequencyrow clearly assigns0500/1005/2=5cycles/s, 5/3=3cycles/s, no load; 200/300 not separately aligned, confirm. No loaded-machine-cycle or installed ingress guarantee. |
| Published flow | 5/2 area/Cv:0500M5=4.25mm²/0.25; 10006=12.3/0.7; 20008=17.9/1.05; 30010=38.4/2.25. Closed 30C:0500M5=3.7/0.2; 10006=10/0.5; 20008=16.2/0.9; 30010=30.5/1.8. 30E/P not individually published; do not inherit closed center. Curves are AirTAC laboratory data. |
| Dimensions / installation | Own terminal-style single/double/three-position drawings, not 7SA or 4SV images. Length A in 0500/100/200/300:single 74.5/100/110/140.5mm; double 103.5/131.5/142/172.5; three 112/143.5/155.5/190.5. Other connector envelopes require actual assembly confirmation. Source specifies 0500 M1.6×14 screw 0.1–0.12N·m; 100/200/300 M2.5×17 screw 0.4–0.45N·m; manual override lock 0.1N·m. |
| Separate manifold / RFQ inputs | Same-size 7SV0500M/100M/200M/300M on source pages 6–7; ordering 1F–30F, dimensions 1F–20F. Independent existing manifold page also supports 7SA from its own source; not an air-pilot valve or solenoid child. Send complete valve/pilot code, voltage, entry, wire length, circuit, manifold/mount, quantity and destination. |
Ordering code matching
Code format
7SV[05/1/2/3][10/20/30C/30E/30P]-[M5/06/08/10][voltage][entry][200][thread]Size-specific pairings and electrical restrictions apply7SV0510-M5B7SV0530C-M5FM7SV110-06A200G7SV230E-08BI7SV330P-10CDT| 1Size / port | 2Action | 3Voltage | 4Entry / wire | 5Thread |
|---|---|---|---|---|
| 05 M5; 1 06; 2 08; 3 10, no alternate pair. | 10/20 5/2; 30C/E/P 5/3; no NC/NO. | 05 A/B/C/F; others A/B/C/E/F. | 05 blank/I/M; others blank/I/D/M. 200 only clear for blank terminal. | 05 no suffix; others blank PT/G G/T NPT. |
AirTAC 7SV 5/2 and 5/3 solenoid valves in 0500/100/200/300 sizes. Confirm 10/20 or 30C/E/P control, main/exhaust ports, voltage, connector and wire length. 0500 excludes AC24V and DIN terminal. Send the code, label or circuit with quantity and destination for quotation.
0500 uses CPSV10 with AC220/AC110/DC24/DC12 and terminal, grommet or M8 entry. It has no AC24V or DIN option. Match 7SV0500M rather than the100/200/300 manifold. Send the actual labels, circuit, connector, station count and destination for confirmation.
7SV
7SV Add other models, quantities, photos, drawings, or a BOM. One request can cover several product groups.
Build your pneumatic circuit with complementary components. Confirm dimensions and operating conditions before selecting a combination.

Product-group reference image
Connect tubing to a valve or actuator. Match tube outside diameter, port thread and seal type.

Product-group reference image
Run air lines between fittings and components. Confirm outside diameter, bend radius, pressure and temperature.

Product-group reference image
Filter and regulate supply air. Confirm filtration, pressure range and flow requirements for the connected equipment.
Send your parts list, connection sizes and operating conditions for a matching check and combined quotation.