Find your CPV10 type
Choose a type; send a model or photo if unsure.
CPV10
Standalone 3/2 micro valve
Send the model, quantity and destination. For multiple items, attach a parts list or BOM.

10 mm direct-acting 3/2 micro-solenoid valves. Match AC/DC voltage, manual override and...
Official reference
Based on manufacturer documentation
Model support
For model confirmation
Parts lists
Code, photo, or BOM
Availability / lead time
By model and quantity
10 mm direct-acting 3/2 micro-solenoid valves. Match AC/DC voltage, manual override and 0.5/2m terminal wire; send label, installation, quantity and destination.
Know your model? Send it with the quantity for a quote. Not sure? Start with a photo, label or description. We help identify the model and clarify availability and lead time. Mixed parts lists are welcome too.
Choose a type; send a model or photo if unsure.
CPV10
Standalone 3/2 micro valve
Send the model, quantity and destination. For multiple items, attach a parts list or BOM.
Match a CPV10 or CPV10S Code
Confirm J03/J04 tubing, stations, valves, terminal wires and blank plates separately.
View base details and request a quote →AirTAC CPV10 official English cpv10 specification
Helpful for Model Matching:
| Identity / supply | CPV10 is a10 mm-body direct-acting 3/2 micro-solenoid valve with push-turn locking manual override and terminal wire. Not an integrated island or a CPV15-sized valve. Symbol shows de-energised A→R and energised P→A; no separately published NC/NO suffix. |
| Voltage / wire ordering | A AC220V, B DC24V, C AC110V, F DC12V; P manual override;050=0.5m,200=2m. Exact example CPV10BP-050. CPVT-050/200 is a separate terminal-wire accessory, not a valve. Valve source says contain two M1.6 screws. AC24V/E, DIN/M8/M12, no-wire or alternate manual codes not published. |
| Pressure / air / protection | Direct acting 0–0.8MPa; proof1.2MPa;−20 to 70°C; air filtered by 40µm element. Nominal boreØ0.55mm. Dustproof, F insulation, not IP65 or explosion-proof rating. DC±10%, AC+15/−10%; DC0.7W, AC1.5VA. Source on<7ms/off<7ms, not full actuator cycle frequency. |
| Flow / direction | Published P→A effective area0.25mm²/Cv0.014; A→R0.35mm²/Cv0.02. Flow curves distinguish these directions; do not quote one flow number without pressure/direction. No lubrication requirement published on this CPV10 table. |
| Mounting / terminal polarity | Own body dimensions width10, overall drawing29.4×24.1mm. Two M1.6×14 screws0.1–0.15N·m; terminal inserted vertical or horizontal and explicitly non-polarity. AC contains full-wave rectifier; do not connect AC coils in series with other devices. These standalone wiring statements do not replace CPV10S D-sub common/pin wiring. |
| Independent manifold / accessories | CPV10M J03(Ø3.2) or J04(Ø4) push-in A ports, P/R=M5;2F–20F. P-CPV10M-R2 blank-plate kit contains plate, gasket and screws. TS15 rail or two M3 mounting screws per source. Manifold/base and occupied/blank stations require separate supply scope; CPV10S integrated island is a different complete ordering architecture. |
Ordering code matching
Code format
CPV10[A/B/C/F]P-[050/200]Complete valve with terminal wireCPV10BP-050CPV10AP-200| 1Identity / supply | 2Voltage / wire ordering | 3Pressure / air / protection | 4Flow / direction |
|---|---|---|---|
| CPV10 is a10 mm-body direct-acting 3/2 micro-solenoid valve with push-turn locking manual override and terminal wire. Not an integrated island or a CPV15-sized valve. Symbol shows de-energised A→R and energised P→A; no separately published NC/NO suffix. | A AC220V, B DC24V, C AC110V, F DC12V; P manual override;050=0.5m,200=2m. Exact example CPV10BP-050. CPVT-050/200 is a separate terminal-wire accessory, not a valve. Valve source says contain two M1.6 screws. AC24V/E, DIN/M8/M12, no-wire or alternate manual codes not published. | Direct acting 0–0.8MPa; proof1.2MPa;−20 to 70°C; air filtered by 40µm element. Nominal boreØ0.55mm. Dustproof, F insulation, not IP65 or explosion-proof rating. DC±10%, AC+15/−10%; DC0.7W, AC1.5VA. Source on<7ms/off<7ms, not full actuator cycle frequency. | Published P→A effective area0.25mm²/Cv0.014; A→R0.35mm²/Cv0.02. Flow curves distinguish these directions; do not quote one flow number without pressure/direction. No lubrication requirement published on this CPV10 table. |
If the label is incomplete, send the readable parts together with a photo.
CPV10BP-0501Identity / supply
CPV10 is a10 mm-body direct-acting 3/2 micro-solenoid valve with push-turn locking manual override and terminal wire. Not an integrated island or a CPV15-sized valve. Symbol shows de-energised A→R and energised P→A; no separately published NC/NO suffix.
2Voltage / wire ordering
A AC220V, B DC24V, C AC110V, F DC12V; P manual override;050=0.5m,200=2m. Exact example CPV10BP-050. CPVT-050/200 is a separate terminal-wire accessory, not a valve. Valve source says contain two M1.6 screws. AC24V/E, DIN/M8/M12, no-wire or alternate manual codes not published.
3Pressure / air / protection
Direct acting 0–0.8MPa; proof1.2MPa;−20 to 70°C; air filtered by 40µm element. Nominal boreØ0.55mm. Dustproof, F insulation, not IP65 or explosion-proof rating. DC±10%, AC+15/−10%; DC0.7W, AC1.5VA. Source on<7ms/off<7ms, not full actuator cycle frequency.
4Flow / direction
Published P→A effective area0.25mm²/Cv0.014; A→R0.35mm²/Cv0.02. Flow curves distinguish these directions; do not quote one flow number without pressure/direction. No lubrication requirement published on this CPV10 table.
10 mm direct-acting 3/2 micro-solenoid valves. Match AC/DC voltage, manual override and 0.5/2m terminal wire; send label, installation, quantity and destination.
CPV10 is a10 mm-body direct-acting 3/2 micro-solenoid valve with push-turn locking manual override and terminal wire. Not an integrated island or a CPV15-sized valve. Symbol shows de-energised A→R and energised P→A; no separately published NC/NO suffix.
Own body dimensions width10, overall drawing29.4×24.1mm. Two M1.6×14 screws0.1–0.15N·m; terminal inserted vertical or horizontal and explicitly non-polarity. AC contains full-wave rectifier; do not connect AC coils in series with other devices. These standalone wiring statements do not replace CPV10S D-sub common/pin wiring.
CPV10
CPV10 Add other models, quantities, photos, drawings, or a BOM. One request can cover several product groups.
Build your pneumatic circuit with complementary components. Confirm dimensions and operating conditions before selecting a combination.

Product-group reference image
Connect tubing to a valve or actuator. Match tube outside diameter, port thread and seal type.

Product-group reference image
Run air lines between fittings and components. Confirm outside diameter, bend radius, pressure and temperature.

Product-group reference image
Filter and regulate supply air. Confirm filtration, pressure range and flow requirements for the connected equipment.
Send your parts list, connection sizes and operating conditions for a matching check and combined quotation.