Pneumatic Model Confirmation & Multi-Brand BOM RFQs|Send the model, quantity and destination
Request a BOM Quote|
PneuPart.com
Industrial Pneumatics
Popular Sourcing Series
SDA Compact CylindersSC Standard Cylinders4V210 Solenoid ValvesAFR Filter RegulatorsPU Tubing (8mm / 6mm)Push-in FittingsZL Vacuum Generators
Fast-Track RFQ Services

BOM Parts List RFQ

Upload Excel spreadsheet or parts list for multi-item direct pricing

Photo & Label Matching

Send photo or nameplate of damaged parts for 1:1 replacement verification

WhatsAppQuote
Popular Sourcing Series
SDA Compact CylindersSC Standard Cylinders4V210 Solenoid ValvesAFR Filter RegulatorsPU Tubing (8mm / 6mm)Push-in FittingsZL Vacuum Generators
Fast-Track RFQ Services

BOM Parts List RFQ

Upload Excel spreadsheet or parts list for multi-item direct pricing

Photo & Label Matching

Send photo or nameplate of damaged parts for 1:1 replacement verification

Product Catalog
PneuPart Products
AirTAC Sourcing
Multi-brand Sourcing
Solutions
Start RFQ
Popular Series:
SCSDA4V210ACQPU Tube
Home/Product Series/AirTAC Sourcing/Standard Cylinders/SCF
AirTAC sourcing reference•Standard Cylinders
SERIESSCF

AirTAC SCF Valve-Equipped Tie-Rod Cylinders

AirTAC SCF scf product official Chinese reference
Series product image
Request a QuoteWhatsAppSend a Photo — We’ll Help Identify It

SCF combines an SC tie-rod cylinder with a mounted 4M210/4M310 valve. Match bore, stroke,...

Official reference

Based on manufacturer documentation

Model support

For model confirmation

Parts lists

Code, photo, or BOM

Availability / lead time

By model and quantity

Sourcing route & inquiry details

SCF combines an SC tie-rod cylinder with a mounted 4M210/4M310 valve. Match bore, stroke, mounting, valve port, coil voltage and wiring; send quantity and destination for an assembly quotation.

Know your model? Send it with the quantity for a quote. Not sure? Start with a photo, label or description. We help identify the model and clarify availability and lead time. Mixed parts lists are welcome too.

Request type
AirTAC originalModel matchingChina-source alternative

Find your SCF type

Choose a type; send a model or photo if unsure.

SCF

Valve-equipped single-rod cylinder

Request a QuoteSend a Photo — We’ll Help Identify It →

Send the model, quantity and destination. For multiple items, attach a parts list or BOM.

Match an SCF Cylinder and Valve Assembly

Drawings & dimensions

Installation Drawings & Technical Specifications

Compare installed dimensions
Full View
AirTAC SCF scf cylinder valve specification official Chinese referenceClick to open full drawing ↗

AirTAC SCF scf cylinder valve specification official Chinese reference

Helpful for Model Matching:

  • Complete original cylinder and valve codes or labels
  • Bore, listed stroke, magnet and TC minimum stroke
  • Valve main/exhaust ports versus cylinder ports; tubing
  • Coil voltage, DIN/lead wire and energised motion direction
  • Complete assembly or separately identified parts; mounting/clearance
  • Quantity and destination
  • Own SCF drawings,not bare SC assembly dimensions
  • Distinguish valve ports, cylinder ports and tubing
  • Confirm voltage,wiring and energised extend/retract mounting
  • TC minimum stroke and TCM1 mating accessory
  • Respect valve pressure limit; valve frequency not assembly cycling

Catalogue Technical Specifications

AirTAC reference data
Identity / supply scopeSCF is an SC single-rod double-acting tie-rod cylinder with a mounted solenoid valve, for one-to-one control. It is not SCLF front-cover locking, SCT multi-position, a locking/safety actuator, or a separate 4M valve. Request the complete cylinder-plus-valve assembly or explicitly identify replacement parts.
Cylinder versus valve pressureCylinder operating 0.15–1.0 MPa, proof 1.5 MPa; valve operating 0.15–0.8 MPa, proof 1.2 MPa. Their common published operating interval is 0.15–0.8 MPa, not cylinder-only 1.0 MPa. Proof pressure is not an operating limit. Internal-pilot valve needs minimum pressure.
Bore-specific standard strokes32 standard 50/75/80/100/125/150/160/175/200/250/300/350/400/450/500 mm; TC starts at 100. 40/50 add 600/700/800/900/1000; TC starts at 100. 63/80/100 standard starts at 75, then 80/100/125/150/160/175/200/250/300/350/400/450/500/600/700/800/900/1000; TC starts at 125. Maximum strokes 32=1000, 40/50=1200, 63/80/100=1500 and allowable column 2000 are not complete standard lists; unlisted custom strokes require consultation.
Valve pairing and distinct port sizes32/40/50 use 4M210-06 or 4M210-08, valve main port 1/8 or 1/4 and exhaust 1/8. 63/80/100 use 4M310-08 or 4M310-10, valve main port 1/4 or 3/8 and exhaust 1/4. Cylinder ports: 32=1/8, 40/50=1/4, 63/80=3/8, 100=1/2. Valve port code 06/08/10 is not the cylinder port. Thread blank PT or G; no NPT T in SCF ordering.
Valve flow / pilot constructionValve is internally piloted, five-port two-position. Effective area/Cv: 4M210-06 14.0 mm²/0.78; 4M210-08 16.0/0.89; 4M310-08 25.0/1.40; 4M310-10 30.0/1.68. These are valve flow characteristics, not cylinder speed or complete-actuator throughput. PU tube OD×ID: 32/40/50 Ø8×5mm; 63/80/100 Ø10×6.5mm.
Electrical ordering / connectorVoltage code A=AC220V, B=DC24V, C=AC110V, E=AC24V, F=DC12V. Blank wiring is DIN connector; I is lead wire. AC tolerance ±15%, DC ±10%; AC 3.5VA, DC 3.0W. IP65(DIN40050) and B insulation are valve electrical source ratings, not a certified protection rating for the complete installed cylinder. Excitation time ≤0.05s; maximum unloaded valve frequency 4M210=5/s, 4M310=4/s is not full-cylinder cycle rate.
Temperature / air / lubricationCylinder and valve −20 to 70°C; cylinder speed 30–800mm/s. Air filtered through 40µm or finer source condition. Valve lubrication not required; if lubricated, do not stop lubrication, source recommends ISO VG32 or equivalent. No H/N high-temperature/seal suffix published in SCF assembly ordering, even though other SC pages publish such fields.
Magnet / mounting / sensorsBlank no magnet or S magnetic piston. Assembly mounting basic/LB/FA/FB/CA/CB/TC; TCM1 is the TC mating accessory, not a complete-cylinder suffix. SCF accessory row: all seven mounting accessories and I/Y/U/F rod joints marked compatible; CMSG/DMSG/EMSG marked compatible only magnetic configuration. Sensor electrical/wire details referenced to printed 409 outside this PDF; confirm exact sensor and bracket before quotation.
Dimensions / cushion / toleranceOwn SCF drawings distinguish energised retract and energised extend layouts. Valve/tubing changes B/BA/BC/BD/CB, FA/AG and clearance; use selected bore/valve-model row, not bare SC drawing. Adjustable cushion stroke32/40/50/63=21mm, 80=28, 100=29. Stroke tolerance0–250 +1.0/0mm, 251–1000 +1.5/0, 1001–1500 +2.0/0; this does not make unlisted strokes standard.
Energised motion / installationSource permits reversing valve mounting by 180° according to whether energisation retracts or extends the rod. A source warning requires alignment of the valve sealing-ring holes and adapter holes. This orientation is not a separate published assembly-order suffix. Confirm required normal/energised motion, pneumatic drawing, valve electrical label and clearance; certified fail-safe behavior is not specified.
Accessory codes / materialsShared SC accessory table printed51–54 supplies F-SC[bore]LB/FA/CA/CB/TC and F-SC[bore]TCM1; FA/FB use F-SC[bore]FA source part number. Rod threads32 M10×1.25, 40 M12×1.25, 50/63 M16×1.5, 80 M20×1.5, 100 M20×1.5. Source I/Y/F/U part numbers use these thread codes; do not append them to SCF assembly code. Shared dimensional sheets depict bare SC bodies and are accessory references only; complete SCF valve clearance follows own drawings.
Common Model Codes & Configurations:Useful for an RFQ
SCF 50 × 1000 S -06 ASCF 80 × 125 S TC -10 B I G

Send the model code, quantity and destination, or attach a parts list.

WhatsAppQuote BOM
Technical reference & selection notes

Ordering Codes, Fit Verification & Specifications

Specifications, installation dimensions, and ordering-code notes.

Ordering code matching

Match each code segment

Send a photo if the code is incomplete

Code format

SCF[bore]×[listed stroke][S][mount]-[06/08/10][A/B/C/E/F][I][G]Complete assembly; valve port and voltage required
SCF 50 × 1000 S -06 ASCF 80 × 125 S TC -10 B I G
1Assembly / bore / stroke2Magnet / mounting3Valve port / voltage / wiring / thread
SCF is an SC single-rod double-acting tie-rod cylinder with a mounted solenoid valve, for one-to-one control. It is not SCLF front-cover locking, SCT multi-position, a locking/safety actuator, or a separate 4M valve. Request the complete cylinder-plus-valve assembly or explicitly identify replacement parts. 32 standard 50/75/80/100/125/150/160/175/200/250/300/350/400/450/500 mm; TC starts at 100. 40/50 add 600/700/800/900/1000; TC starts at 100. 63/80/100 standard starts at 75, then 80/100/125/150/160/175/200/250/300/350/400/450/500/600/700/800/900/1000; TC starts at 125. Maximum strokes 32=1000, 40/50=1200, 63/80/100=1500 and allowable column 2000 are not complete standard lists; unlisted custom strokes require consultation.Blank no magnet or S magnetic piston. Assembly mounting basic/LB/FA/FB/CA/CB/TC; TCM1 is the TC mating accessory, not a complete-cylinder suffix. SCF accessory row: all seven mounting accessories and I/Y/U/F rod joints marked compatible; CMSG/DMSG/EMSG marked compatible only magnetic configuration. Sensor electrical/wire details referenced to printed 409 outside this PDF; confirm exact sensor and bracket before quotation.32/40/50 use 4M210-06 or 4M210-08, valve main port 1/8 or 1/4 and exhaust 1/8. 63/80/100 use 4M310-08 or 4M310-10, valve main port 1/4 or 3/8 and exhaust 1/4. Cylinder ports: 32=1/8, 40/50=1/4, 63/80=3/8, 100=1/2. Valve port code 06/08/10 is not the cylinder port. Thread blank PT or G; no NPT T in SCF ordering. Voltage code A=AC220V, B=DC24V, C=AC110V, E=AC24V, F=DC12V. Blank wiring is DIN connector; I is lead wire. AC tolerance ±15%, DC ±10%; AC 3.5VA, DC 3.0W. IP65(DIN40050) and B insulation are valve electrical source ratings, not a certified protection rating for the complete installed cylinder. Excitation time ≤0.05s; maximum unloaded valve frequency 4M210=5/s, 4M310=4/s is not full-cylinder cycle rate.

Avoid a wrong match

  • SCF valve-equipped is not SCLF front-locking.
  • Cylinder1.0MPa rating cannot override valve0.8MPa.
  • Valve port code is independent of cylinder port.
  • Maximum/allowable stroke columns are not standard lists.
  • TC has longer minimum stroke; TCM1 is accessory.
  • Valve IP65/frequency is not whole-actuator certification/cycle rate.
  • No SC H/N seal option or NPT T copied into SCF ordering.

Read the model code

If the label is incomplete, send the readable parts together with a photo.

SCF 50 × 1000 S -06 A

1Assembly / bore / stroke

SCF is an SC single-rod double-acting tie-rod cylinder with a mounted solenoid valve, for one-to-one control. It is not SCLF front-cover locking, SCT multi-position, a locking/safety actuator, or a separate 4M valve. Request the complete cylinder-plus-valve assembly or explicitly identify replacement parts. 32 standard 50/75/80/100/125/150/160/175/200/250/300/350/400/450/500 mm; TC starts at 100. 40/50 add 600/700/800/900/1000; TC starts at 100. 63/80/100 standard starts at 75, then 80/100/125/150/160/175/200/250/300/350/400/450/500/600/700/800/900/1000; TC starts at 125. Maximum strokes 32=1000, 40/50=1200, 63/80/100=1500 and allowable column 2000 are not complete standard lists; unlisted custom strokes require consultation.

2Magnet / mounting

Blank no magnet or S magnetic piston. Assembly mounting basic/LB/FA/FB/CA/CB/TC; TCM1 is the TC mating accessory, not a complete-cylinder suffix. SCF accessory row: all seven mounting accessories and I/Y/U/F rod joints marked compatible; CMSG/DMSG/EMSG marked compatible only magnetic configuration. Sensor electrical/wire details referenced to printed 409 outside this PDF; confirm exact sensor and bracket before quotation.

3Valve port / voltage / wiring / thread

32/40/50 use 4M210-06 or 4M210-08, valve main port 1/8 or 1/4 and exhaust 1/8. 63/80/100 use 4M310-08 or 4M310-10, valve main port 1/4 or 3/8 and exhaust 1/4. Cylinder ports: 32=1/8, 40/50=1/4, 63/80=3/8, 100=1/2. Valve port code 06/08/10 is not the cylinder port. Thread blank PT or G; no NPT T in SCF ordering. Voltage code A=AC220V, B=DC24V, C=AC110V, E=AC24V, F=DC12V. Blank wiring is DIN connector; I is lead wire. AC tolerance ±15%, DC ±10%; AC 3.5VA, DC 3.0W. IP65(DIN40050) and B insulation are valve electrical source ratings, not a certified protection rating for the complete installed cylinder. Excitation time ≤0.05s; maximum unloaded valve frequency 4M210=5/s, 4M310=4/s is not full-cylinder cycle rate.

About SCF

SCF combines an SC tie-rod cylinder with a mounted 4M210/4M310 valve. Match bore, stroke, mounting, valve port, coil voltage and wiring; send quantity and destination for an assembly quotation.

Matching Questions

Is SCF the same as SCLF front-locking?

SCF is an SC single-rod double-acting tie-rod cylinder with a mounted solenoid valve, for one-to-one control. It is not SCLF front-cover locking, SCT multi-position, a locking/safety actuator, or a separate 4M valve. Request the complete cylinder-plus-valve assembly or explicitly identify replacement parts.

May the valve-equipped assembly use the cylinder 1.0MPa limit?

Cylinder operating 0.15–1.0 MPa, proof 1.5 MPa; valve operating 0.15–0.8 MPa, proof 1.2 MPa. Their common published operating interval is 0.15–0.8 MPa, not cylinder-only 1.0 MPa. Proof pressure is not an operating limit. Internal-pilot valve needs minimum pressure.

SCF

Include this series in a project RFQ

SCF Add other models, quantities, photos, drawings, or a BOM. One request can cover several product groups.

Request a project quoteWhatsAppSend a parts list or BOM
Confirm inspection requirements before quotation•Specify shipping preference•Confirm timing in the quotation•Ocean & Rail Available
COMPANION PRODUCTS

Products to use together

Build your pneumatic circuit with complementary components. Confirm dimensions and operating conditions before selecting a combination.

Directional control valves
Control air direction

Product-group reference image

Directional control valves

Switch the pneumatic circuit. Select the valve function, flow capacity, port size and control signal for the application.

View companion product
PneuPart SL speed controllers
Adjust actuator speed

Product-group reference image

PneuPart SL speed controllers

Control actuator air flow. Confirm thread, tube size, flow direction and required flow rate.

View companion product
PneuPart tube fittings
Connect the air line

Product-group reference image

PneuPart tube fittings

Connect tubing to a valve or actuator. Match tube outside diameter, port thread and seal type.

View companion product
PneuPart pneumatic tubing
Route the air supply

Product-group reference image

PneuPart pneumatic tubing

Run air lines between fittings and components. Confirm outside diameter, bend radius, pressure and temperature.

View companion product

Planning a Complete Circuit or Multi-Item BOM?

Send your parts list, connection sizes and operating conditions for a matching check and combined quotation.

Submit Multi-Item Circuit RFQ

Pneupart

Pneupart is a China-based pneumatic sourcing brand for distributors, factories, and MRO buyers. Send a model, label, drawing or BOM for technical confirmation and quotation. Specify whether original AirTAC sourcing or an alternative is required.

Product Series

Cylinder SeriesSolenoid Valve SeriesQuick Connect FittingsAirTAC Sourcing

Company

About UsContact UsSupplier VerificationAlibaba.com ProfileAirTAC Partner Lookup

RFQ Support

SolutionsMulti-brand SourcingAirTAC Replacement

Contact

Email: [email protected]

WhatsApp: +86 177 0867 3949

Address: C701, 7th Floor, Building C, Shunyijia Intelligent Technology Park, No. 22 Huaxing Road, Zhangcha Street, Foshan, Guangdong, China

Quotation Notes:Include quantities, destination and requested delivery date in the RFQ.•Availability, shipping method, timing and trade terms are confirmed in the quotation.•Specify inspection and packaging requirements where they affect the request.
About PneupartPrivacyRFQ Terms

Pneupart is operated by Guangdong Wanjing Automation Technology Co., Ltd., Foshan, China.