Pneumatic Model Confirmation & Multi-Brand BOM RFQs|Send the model, quantity and destination
Request a BOM Quote|
PneuPart.com
Industrial Pneumatics
Popular Sourcing Series
SDA Compact CylindersSC Standard Cylinders4V210 Solenoid ValvesAFR Filter RegulatorsPU Tubing (8mm / 6mm)Push-in FittingsZL Vacuum Generators
Fast-Track RFQ Services

BOM Parts List RFQ

Upload Excel spreadsheet or parts list for multi-item direct pricing

Photo & Label Matching

Send photo or nameplate of damaged parts for 1:1 replacement verification

WhatsAppQuote
Popular Sourcing Series
SDA Compact CylindersSC Standard Cylinders4V210 Solenoid ValvesAFR Filter RegulatorsPU Tubing (8mm / 6mm)Push-in FittingsZL Vacuum Generators
Fast-Track RFQ Services

BOM Parts List RFQ

Upload Excel spreadsheet or parts list for multi-item direct pricing

Photo & Label Matching

Send photo or nameplate of damaged parts for 1:1 replacement verification

Product Catalog
PneuPart Products
AirTAC Sourcing
Multi-brand Sourcing
Solutions
Start RFQ
Popular Series:
SCSDA4V210ACQPU Tube
Home/Product Series/AirTAC Sourcing/Standard Cylinders/SCL
AirTAC sourcing reference•Standard Cylinders
SERIESSCL

AirTAC SCL End-Lock Cylinder Family

AirTAC SCL product rear official Chinese reference
Series product image
Request a QuoteWhatsAppSend a Photo — We’ll Help Identify It

SCL end-lock cylinders support SCLB rear-cover and SCLF front-cover locking, bores 40–100 mm....

Official reference

Based on manufacturer documentation

Model support

For model confirmation

Parts lists

Code, photo, or BOM

Availability / lead time

By model and quantity

Sourcing route & inquiry details

SCL end-lock cylinders support SCLB rear-cover and SCLF front-cover locking, bores 40–100 mm. Match lock side, bore-specific standard stroke, magnet, mounting and PT/G ports; send the model and release circuit for quotation. Locking requires reaching the locking-side stroke end.

Know your model? Send it with the quantity for a quote. Not sure? Start with a photo, label or description. We help identify the model and clarify availability and lead time. Mixed parts lists are welcome too.

Request type
AirTAC originalModel matchingChina-source alternative

Find your SCL type

Choose a type; send a model or photo if unsure.

SCLB

Rear-cover end lock

SCLF

Front-cover end lock

Request a QuoteSend a Photo — We’ll Help Identify It →

Send the model, quantity and destination. For multiple items, attach a parts list or BOM.

Match an SCL Model and End-Lock Requirement

Drawings & dimensions

Installation Drawings & Technical Specifications

Compare installed dimensions
Full View
AirTAC SCL specification official Chinese referenceClick to open full drawing ↗

AirTAC SCL specification official Chinese reference

Helpful for Model Matching:

  • Complete SCLB/SCLF model or label
  • Rear/front lock position and locking-side stroke end
  • Bore-specific standard stroke, magnet and mounting
  • Cylinder ports, release valve circuit and actual load
  • Installation drawing, quantity and destination
  • Match SCLB rear/SCLF front lock position with its dedicated picture and drawing.
  • Check bore-specific stroke, lock-side versus other-end cushion and ports.
  • Confirm the end-lock release circuit and actual load; not arbitrary-position clamping.

Catalogue Technical Specifications

AirTAC reference data
Identity / lock positionSCL is an SC tie-rod double-acting cylinder with end locking. SCLB = rear-cover lock, SCLF = front-cover lock. These are not the BSC rod-clamp family. The piston must reach the locking-side stroke end; this is not arbitrary-position holding.
Published bores / strokesBores 40/50/63/80/100 mm. Bore 40 standard strokes: 25/50/75/80/100/125/150/160/175/200/250/300/350/400/450/500/600/700/800 mm. Other bores add 900/1000. Maximum columns: 40/50 = 1200, 63/80/100 = 1500; allowable column 1800 for all. These maxima do not turn unlisted strokes into standard choices.
Pressure / air / temperatureOperating pressure 0.15–1.0 MPa, proof 1.5 MPa; speed 30–800 mm/s. Air filtered through 40 μm; −20 to 70°C. BSC 0.7 MPa maximum and its static holding-force/unlocking-pressure values do not apply to SCL; these values are not listed in the SCL table.
Cylinder ports40/50 ports 1/4, 63/80 3/8, 100 1/2. Blank PT or G; no NPT T in ordering table. Release operates through the actual cylinder circuit; no separate G1/8 lock port is inferred from BSC.
Cushion end-specificAdjustable cushion. Unlocked-side cushion: 40/50/63 = 21 mm, 80 = 28, 100 = 29. Locked-side cushion: 40 = 17, 50/63 = 18, 80 = 20.5, 100 = 22. Cushion length depends on bore and locked or unlocked side.
End-specific drawingsSCLB rear lock and SCLF front lock have separate product images and drawings. SCLB drawing uses A+stroke; SCLF drawing labels A+2×stroke and AB+stroke. Preserve the original drawing and confirm actual installation; do not silently replace that expression or mislabel SCLF as double rod. Magnet and non-magnet dimensions are the same.
Release circuit / limitsSupply the unlocking-side B port and release without load on the locking mechanism. The source advises against quick exhaust and three-position valves, especially closed-center metal-seal valves; residual pressure/leakage or lock-side back pressure can prevent locking or release it. Use the specified individual-exhaust valve arrangement and meter-out control; verify the actual circuit.
Maintenance / operationAvoid excessive locked-side cushion restriction; unlock for installation/adjustment. Return manual release mechanism to its initial position and use manual operation only during adjustment. Do not drive one workpiece with two or more lock cylinders. Manual release example requires pull force >=20 N with unloaded horizontal installation or opposite-port pressurization; this is a manual-release condition, not holding capacity.
Unpublished capacityThis two-page source gives no static holding-force table, certified safety category or dynamic braking rating. Send load, lock position, circuit, mounting, quantity and destination for confirmation. Structure/material drawing is a specific bore example, not a universal BOM.
Common Model Codes & Configurations:Useful for an RFQ
SCLB50×50SSCLF63×100SFAG

Send the model code, quantity and destination, or attach a parts list.

WhatsAppQuote BOM
Technical reference & selection notes

Ordering Codes, Fit Verification & Specifications

Specifications, installation dimensions, and ordering-code notes.

Ordering code matching

Match each code segment

Send a photo if the code is incomplete

Code format

SCL [B/F] [bore] × [standard stroke] [S] [mounting] [G]Lock position is mandatory; blank magnet/PT supported
SCLB50×50SSCLF63×100SFAG
1SCLB / SCLF2Bore / stroke3Magnet / mounting4Thread
B rear cover; F front cover; lock side must be specified40/50/63/80/100; use bore-specific standard row, not max/allowable columnBlank or S; basic/LB/FA/FB/CA/CB/TC; TCM1 separate accessoryBlank PT or G, no NPT T

Avoid a wrong match

  • SCL end lock is not BSC arbitrary-position rod clamping.
  • B/F is mandatory; rear/front images and cushion lengths differ.
  • Maximum/allowable 1200/1500/1800 mm do not define standard-stroke inventory.
  • No holding force, separate G1/8 lock port or BSC release pressure is published here.
  • Three-position valves, quick exhaust and lock-side back pressure can defeat the intended lock/release function.

Read the model code

If the label is incomplete, send the readable parts together with a photo.

SCLB 50 × 50 S

SCLBSCLB / SCLF

B rear cover; F front cover; lock side must be specified

50×50Bore / stroke

40/50/63/80/100; use bore-specific standard row, not max/allowable column

SMagnet / mounting

Blank or S; basic/LB/FA/FB/CA/CB/TC; TCM1 separate accessory

PTThread

Blank PT or G, no NPT T

About SCL

SCL end-lock cylinders support SCLB rear-cover and SCLF front-cover locking, bores 40–100 mm. Match lock side, bore-specific standard stroke, magnet, mounting and PT/G ports; send the model and release circuit for quotation. Locking requires reaching the locking-side stroke end.

Matching Questions

Can SCL lock at any intermediate position?

The source requires the piston to reach the locking-side stroke end. Match SCLB rear or SCLF front end and confirm the release circuit; use a different family inquiry for arbitrary-position requirements.

Is 1800 mm a standard stroke?

It is an allowable-column value, not the explicit standard-stroke list. Send a custom requirement and installation drawing for confirmation.

SCL

Include this series in a project RFQ

SCL Add other models, quantities, photos, drawings, or a BOM. One request can cover several product groups.

Request a project quoteWhatsAppSend a parts list or BOM
Confirm inspection requirements before quotation•Specify shipping preference•Confirm timing in the quotation•Ocean & Rail Available
COMPANION PRODUCTS

Products to use together

Build your pneumatic circuit with complementary components. Confirm dimensions and operating conditions before selecting a combination.

Directional control valves
Control air direction

Product-group reference image

Directional control valves

Switch the pneumatic circuit. Select the valve function, flow capacity, port size and control signal for the application.

View companion product
PneuPart SL speed controllers
Adjust actuator speed

Product-group reference image

PneuPart SL speed controllers

Control actuator air flow. Confirm thread, tube size, flow direction and required flow rate.

View companion product
PneuPart tube fittings
Connect the air line

Product-group reference image

PneuPart tube fittings

Connect tubing to a valve or actuator. Match tube outside diameter, port thread and seal type.

View companion product
PneuPart pneumatic tubing
Route the air supply

Product-group reference image

PneuPart pneumatic tubing

Run air lines between fittings and components. Confirm outside diameter, bend radius, pressure and temperature.

View companion product

Planning a Complete Circuit or Multi-Item BOM?

Send your parts list, connection sizes and operating conditions for a matching check and combined quotation.

Submit Multi-Item Circuit RFQ

Pneupart

Pneupart is a China-based pneumatic sourcing brand for distributors, factories, and MRO buyers. Send a model, label, drawing or BOM for technical confirmation and quotation. Specify whether original AirTAC sourcing or an alternative is required.

Product Series

Cylinder SeriesSolenoid Valve SeriesQuick Connect FittingsAirTAC Sourcing

Company

About UsContact UsSupplier VerificationAlibaba.com ProfileAirTAC Partner Lookup

RFQ Support

SolutionsMulti-brand SourcingAirTAC Replacement

Contact

Email: [email protected]

WhatsApp: +86 177 0867 3949

Address: C701, 7th Floor, Building C, Shunyijia Intelligent Technology Park, No. 22 Huaxing Road, Zhangcha Street, Foshan, Guangdong, China

Quotation Notes:Include quantities, destination and requested delivery date in the RFQ.•Availability, shipping method, timing and trade terms are confirmed in the quotation.•Specify inspection and packaging requirements where they affect the request.
About PneupartPrivacyRFQ Terms