| Identity / bearings | SAI standard cylinder plus a separate dual-guide-rod frame. M is brass bearing, not steel-ball; L is linear bearing. The two guide rods do not make it a double piston-rod cylinder. |
| Bearing decision | M: radial load resistance and greater torsional stiffness. L: push-up action, high precision/load demand and low friction. Use the separate M/L maximum-load curves; do not assume one is always stronger. |
| Standard stroke / ordering | Bores32/40/50/63/80/100; all list50/100/150/200/250/300/350/400/450/500mm only. TSAI M/L + bore×listed stroke + optionalS + optionalG. Blank no magnet and PT; noT or mounting suffix here. |
| Pressure / air / temperature | Double acting,40μm filtered air,0.15–1.0MPa operating,1.5MPa proof,−20..70°C,30–500mm/s. Proof is not working pressure; lubrication not stated here. |
| Ports / cushion / tolerance | 32=1/8;40/50=1/4;63/80=3/8;100=1/2,PT blank orG. Variable cushion. Stroke0–250 tolerance+1/0mm;>250 +1.5/0. Tolerance does not publish additional standard strokes. |
| Cylinder thrust / guide load | At0.5MPa push/pullN:32 402/345;40 628/527.5;50 981.5/824.5;63 1558.5/1401.5;80 2513/2268;100 3926.5/3681. The source thrust table includes0.1MPa but the operating minimum is0.15MPa. Thrust is not guide load capacity or payloadkg. |
| Load curve condition | Maximum guide load F(N) depends on M/L bearing, bore and diagram lever distanceS(mm), plotted0–500mm. S here is the load distance, not the magnet suffix. No scalar payload, moment or automatic interpolation approval; send actual load/orientation/lever distance and installation drawing. |
| Separate frame / non-standard | F-TSAI M/L bore×stroke is guide-frame accessory, not complete cylinder. Separate frame standard list matches published strokes. For a non-standard cylinder, source says use frame of upper standard stroke; exampleSAI32×160 +F-TSAIM32×200. Cylinder A+160 and frame AC+200 are independent lengths; original combination requires confirmation. |
| Sensor holders / switches | S magnetic cylinder includes2sensor holders; separately ordered guide frame also includes2holders. F-TSAI32E=32/40;F-TSAI50E=50/63;F-TSAI80E=80/100. CMSE/DMSE shown as switch choices; holders do not mean switches included. No absent-magnet switch promise. |
| Dimensions / material | TSAIM/TSAIL shared drawing; parenthesized values belong to TSAIL, notably guide diameterD32/40 20(16),80/100 30(25). Missing dimension cells stay unspecified. Confirm multiple-direction threaded/through-hole mounting and A+stroke/AC+stroke/AF+stroke. Material drawing based on a certain bore; do not use as universal BOM. |