Pneumatic Model Confirmation & Multi-Brand BOM RFQs|Send the model, quantity and destination
Request a BOM Quote|
PneuPart.com
Industrial Pneumatics
Popular Sourcing Series
SDA Compact CylindersSC Standard Cylinders4V210 Solenoid ValvesAFR Filter RegulatorsPU Tubing (8mm / 6mm)Push-in FittingsZL Vacuum Generators
Fast-Track RFQ Services

BOM Parts List RFQ

Upload Excel spreadsheet or parts list for multi-item direct pricing

Photo & Label Matching

Send photo or nameplate of damaged parts for 1:1 replacement verification

WhatsAppQuote
Popular Sourcing Series
SDA Compact CylindersSC Standard Cylinders4V210 Solenoid ValvesAFR Filter RegulatorsPU Tubing (8mm / 6mm)Push-in FittingsZL Vacuum Generators
Fast-Track RFQ Services

BOM Parts List RFQ

Upload Excel spreadsheet or parts list for multi-item direct pricing

Photo & Label Matching

Send photo or nameplate of damaged parts for 1:1 replacement verification

Product Catalog
PneuPart Products
AirTAC Sourcing
Multi-brand Sourcing
Solutions
Start RFQ
Popular Series:
SCSDA4V210ACQPU Tube
Home/Product Series/AirTAC Sourcing/Welding Clamp Cylinders/JSCK
AirTAC sourcing reference•Welding Clamp Cylinders
SERIESJSCK

AirTAC JSCK Power Clamp Cylinders

AirTAC JSCK official standard product
Series product image
Request a QuoteWhatsAppSend a Photo — We’ll Help Identify It

JSCK double-acting power clamps use a crank-slider and conditional end-position self-lock....

Official reference

Based on manufacturer documentation

Model support

For model confirmation

Parts lists

Code, photo, or BOM

Availability / lead time

By model and quantity

Sourcing route & inquiry details

JSCK double-acting power clamps use a crank-slider and conditional end-position self-lock. Compare standard and HL/HR manual construction, fixed angle, arm and fixture; send the code, load, pressure, quantity and destination for a quotation.

Know your model? Send it with the quantity for a quote. Not sure? Start with a photo, label or description. We help identify the model and clarify availability and lead time. Mixed parts lists are welcome too.

Request type
AirTAC originalModel matchingChina-source alternative

Find your JSCK type

Choose a type; send a model or photo if unsure.

JSCK

Standard pneumatic power clamp

JSCK-H

Manual HL/HR handle construction

View details →
Request a QuoteSend a Photo — We’ll Help Identify It →

Send the model, quantity and destination. For multiple items, attach a parts list or BOM.

Match a JSCK clamp model

Drawings & dimensions

Installation Drawings & Technical Specifications

Compare installed dimensions
Full View
AirTAC JSCK official family overviewClick to open full drawing ↗

AirTAC JSCK official family overview

Helpful for Model Matching:

  • JSCK full code or label; standard or HL/HR manual
  • Horizontal/V vertical, bore and fixed opening angle
  • Arm AM1–AM4 and R/C/L; intended fixture/washer setup
  • Arm mass/offset, length, working pressure and clamp load
  • PNP/NPN sensor, connector, PT/G and blank/B port position
  • Quantity and destination
  • Match standard or manual handle-specific drawing
  • Check fixed angle and arm/position-specific limits
  • Confirm pressure, arm mass/length, fixture washer and dead-point locking
  • Separate arm kits, DIST sensor and cable/connector from clamp model

Catalogue Technical Specifications

AirTAC reference data
Pressure / medium / proofDouble acting; 0.3–0.8 MPa; 40 μm filtered air; proof 1.2 MPa; −20–70°C; air buffering; minimum 1 second clamp and 1 second open
Published output torque at 0.5MPaStandard specification40/50/63/80=120/160/380/800 N·m; manual 40/50/63=120/160/380 N·m. Selection table at 0.5MPa gives120/165/400/804 N·m; confirm operating point instead of treating these as guaranteed clamp force
Maximum holder torque40/50/63/80=380/800/1500/2500 N·m at final clamping position; distinct from output torque and arm bolt tightening torque
Arm load torque, 1s /2s period40=2.2/3.3; 50=4.5/6.7; 63=6.0/9.0; 80=8.0/11.2 N·m. Check arm weight and center-of-mass offset against source curves
Standard angle limits40 horizontal AM1≤135, AM3≤105; vertical AM1≤120, AM3≤105.50/63/80 horizontal all arms≤135; vertical≤105. No-arm angles above 105 require fixture confirmation
Manual angle limits40 horizontal/vertical AM1/AM3≤105 per ordering table.50/63 horizontal AM1–AM4≤120; vertical≤105. No80 manual.40 drawing arcs conflict with ordering table; higher angles require confirmation
Port / arm offsets40 PT/G1/8; 50/63/80 PT/G1/4. AM1/AM2 offset 15mm except80 offset 20mm; AM3/AM4 offset 45mm. Arms have R/C/L position-specific hole patterns
Sensor / connectorK PNP, KN NPN. DIST-P/N63 for 40/50/63; DIST-P/N80 for 80.10–30V DC, N.O., rated150mA max, IP64, 2mm sensing range. Cable/connector separately selected
Arm bolt tightening torque40/50:M6×1.0, 13.8 N·m; 63:M8×1.25, 33.0; 80:M10×1.5, 66.0. Not holder or clamp torque
Self-lock / fixtureSelf-lock occurs only after crank-slider passes dead point at final closure; washer thickness beyond final torque position can defeat locking. Standard unlock: air or retaining pin; manual also handle. Releasing pin can cause arm spring-out; keep clear of motion range
Common Model Codes & Configurations:Useful for an RFQ
JSCK50×135AM1RKGBJSCKV40×120AM1RJSCK80×135AM4LKN

Send the model code, quantity and destination, or attach a parts list.

WhatsAppQuote BOM
Technical reference & selection notes

Ordering Codes, Fit Verification & Specifications

Specifications, installation dimensions, and ordering-code notes.

Ordering code matching

Match each code segment

Send a photo if the code is incomplete

Code format

JSCK [V] [bore] × [fixed angle] [AM1–AM4 + R/C/L] [HL/HR] [K/KN] [G] [B]Manual HL/HR routes to the manual construction; accessories ordered separately
JSCK50×135AM1RKGBJSCKV40×120AM1RJSCK80×135AM4LKN
1Position2Bore / fixed angle3Clamp arm4Manual handle5Sensor6Thread / port position
Blank horizontal; V vertical.Standard 40/50/63/80; manual 40/50/63. Fixed 15/30/45/60/75/90/105/120/135°, subject to arm/position/type limits.Blank no arm; 40 only AM1/AM3; 50/63/80 AM1–AM4, each R/C/L. AM1/2 offset 15mm except80 offset 20mm; AM3/4 offset 45mm.Blank standard; HL handle left, HR right. Manual excludes80 and has stricter angle limits.Blank no sensor; K electrical PNP; KN electrical NPN. Separate DIST accessories and connector/cable selection.Blank PT; G available.40 port1/8, 50/63/80 port1/4. Blank or B port position. No NPT code here.

Avoid a wrong match

  • JSCK is distinct from JCK and JSK. Do not map their clamp code or drawing to this family.
  • Opening angle is fixed by construction/barrel length. Select a published angle within the arm, position and standard/manual limit.
  • HL/HR manual types exclude bore 80; 40 supports only AM1/AM3. Arm side R/C/L is separate from left/right handle HL/HR.
  • PT/G only; blank/B port position is a separate field, not the opening angle.
  • Output torque, final holder torque, arm load torque and bolt tightening torque are different. Specification and selection torque tables differ; confirm pressure, arm length and fixture.
  • Self-lock requires passing the dead point at final closure. Spacer/fixture setup can prevent it; loss of air alone does not establish safe locking.
  • K/KN refer to PNP/NPN inductive sensors, not piston magnets. DIST kit and cable/connector are separate selections.

Read the model code

If the label is incomplete, send the readable parts together with a photo.

JSCK50×135AM1RKGB

1Position

Blank horizontal; V vertical.

2Bore / fixed angle

Standard 40/50/63/80; manual 40/50/63. Fixed 15/30/45/60/75/90/105/120/135°, subject to arm/position/type limits.

3Clamp arm

Blank no arm; 40 only AM1/AM3; 50/63/80 AM1–AM4, each R/C/L. AM1/2 offset 15mm except80 offset 20mm; AM3/4 offset 45mm.

4Manual handle

Blank standard; HL handle left, HR right. Manual excludes80 and has stricter angle limits.

5Sensor

Blank no sensor; K electrical PNP; KN electrical NPN. Separate DIST accessories and connector/cable selection.

6Thread / port position

Blank PT; G available.40 port1/8, 50/63/80 port1/4. Blank or B port position. No NPT code here.

About JSCK

JSCK double-acting power clamps use a crank-slider and conditional end-position self-lock. Compare standard and HL/HR manual construction, fixed angle, arm and fixture; send the code, load, pressure, quantity and destination for a quotation.

Matching Questions

Does self-lock mean any loss of air leaves the clamp safely locked?

Only the correctly set mechanism that has passed the dead point at final closure self-locks. Confirm spacer thickness, fixture and retaining-pin state; manual handles add a separate clamp/unlock method. This is not a safety certification.

JSCK

Include this series in a project RFQ

JSCK Add other models, quantities, photos, drawings, or a BOM. One request can cover several product groups.

Request a project quoteWhatsAppSend a parts list or BOM
Confirm inspection requirements before quotation•Specify shipping preference•Confirm timing in the quotation•Ocean & Rail Available
COMPANION PRODUCTS

Products to use together

Build your pneumatic circuit with complementary components. Confirm dimensions and operating conditions before selecting a combination.

Directional control valves
Control air direction

Product-group reference image

Directional control valves

Switch the pneumatic circuit. Select the valve function, flow capacity, port size and control signal for the application.

View companion product
PneuPart SL speed controllers
Adjust actuator speed

Product-group reference image

PneuPart SL speed controllers

Control actuator air flow. Confirm thread, tube size, flow direction and required flow rate.

View companion product
PneuPart tube fittings
Connect the air line

Product-group reference image

PneuPart tube fittings

Connect tubing to a valve or actuator. Match tube outside diameter, port thread and seal type.

View companion product
PneuPart pneumatic tubing
Route the air supply

Product-group reference image

PneuPart pneumatic tubing

Run air lines between fittings and components. Confirm outside diameter, bend radius, pressure and temperature.

View companion product

Planning a Complete Circuit or Multi-Item BOM?

Send your parts list, connection sizes and operating conditions for a matching check and combined quotation.

Submit Multi-Item Circuit RFQ

Pneupart

Pneupart is a China-based pneumatic sourcing brand for distributors, factories, and MRO buyers. Send a model, label, drawing or BOM for technical confirmation and quotation. Specify whether original AirTAC sourcing or an alternative is required.

Product Series

Cylinder SeriesSolenoid Valve SeriesQuick Connect FittingsAirTAC Sourcing

Company

About UsContact UsSupplier VerificationAlibaba.com ProfileAirTAC Partner Lookup

RFQ Support

SolutionsMulti-brand SourcingAirTAC Replacement

Contact

Email: [email protected]

WhatsApp: +86 177 0867 3949

Address: C701, 7th Floor, Building C, Shunyijia Intelligent Technology Park, No. 22 Huaxing Road, Zhangcha Street, Foshan, Guangdong, China

Quotation Notes:Include quantities, destination and requested delivery date in the RFQ.•Availability, shipping method, timing and trade terms are confirmed in the quotation.•Specify inspection and packaging requirements where they affect the request.
About PneupartPrivacyRFQ Terms

Pneupart is operated by Guangdong Wanjing Automation Technology Co., Ltd., Foshan, China.