AirTAC CPV15M Manifold Bases
Bases for individual CPV15 valves with terminal wires. Specify 2–20 stations, thread, push-in tubing, populated positions and blank plates for quotation.

Valve, Station and Port Matching
| Base | Valve | A tube | Stations | P/R |
|---|---|---|---|---|
| CPV15M / G | CPV15 | 4mm | 2–20 | 1/8 PT / G |
| CPV15M T | CPV15 | 5/32 inch | 2–20 | 1/8 NPT |
CPV15M publishes every integer station count from 2 to 20. A tube diameter is not an A port thread. CPV15S is a separate 25-pin D-Sub assembly with even stations and DC supply; its electrical assembly is not inferred from this base code.
CPV15 →Supply Scope and Mounting
CPV15M20FG · P-CPV15S-R2.
The CPV15M ordering note lists manifold and blank plate. Confirm valves, wires and occupied/unused stations separately. Published blank-plate kit P-CPV15S-R2 includes plate, gasket and screw; keep the source S designation when requesting this supporting accessory.
Valve fixed with two M2.5 screws; blank plate with two M2.5 countersunk screws; base through two mounting holes with M4 screws. Own CPV15M drawing: 15.5mm station pitch, 2–20 stations. Air filtered to 40μm, −20 to 70°C. No independent base pressure or electrical rating is published; confirm actual system conditions.